Specifications
Chapter3
Installation
America’sFavoriteStovesSince1980 Page10
Optional Blower Installation
WARNING:Electrical Grounding Instructions.Thisappliance isequippedwithathree‐prong (grounding) plug
foryourprotectionagainstshockhazardandshouldbepluggeddirectlyintoaproperlygroundedthree‐prong
receptacle.Donotcutorremovethegroundingprongfromthisplug.
Theblowerkitcontainsablowerassembly
andspeedcontrolunit.
W3100‐FreestandingUnits
WARNING:Neveroperatethestovewithouteithertheblowerortheblower coverinplace.
1. With a hammer remove the two knockouts in
therearbottomofthefirebox.
2. Insert the two 1/4‐20 x 1” bolts with washer
andpartially
tighten.
3. Hold the blower on both sides and allow the
screw heads to go through the slots and move
theblowertotherightasmuchaspossible.
4. Tightenboltswith7/16”wrench.
5. Route the fan cordsothatitisnot cominginto
contactwithany
partifthestove.
W3100‐InsertUnits
WARNING:Neveroperatethestovewithouteithertheblowerortheblower coverinplace.
1. Remove the cover plate under the ash lip with
5/32”allenwrench.
2. Remove the top cover of blower housing by
removing the 6 hex head
screws holding it in
place.
3. Insertthetwo1/4‐20x1”boltswithwasherand
partiallytighten.
4. Hold the blower on both sides and allow the
screw heads to go through the slots and move
theblowertotherightasmuchaspossible.
5. Tightenbolts
with7/16”wrench.
6. Route the fan cord so that it is not coming into
contactwithanypartifthestove.