Specifications
Chapter1
Specifications&Clearances
America’sFavoriteStovesSince1980 Page6
Minimumclearancetocombustiblemustbemaintainedasshowninfigure2andthefollowingchart.
A B* C D* E* F G H
SingleWallConnector 24” 14” 16” 14” 7” 16” 84” 30”
DoubleWallConnector 22” 12‐1/2” 12” 10” 7” 16” 84” 30”
AlcovewithDoubleWall 22” 12‐1/2” 12” 10” 7” 16” 84” 30”
MobileHomeDoubleWall 22” 12‐1/2” 12” 10” 7” 16” 84” 30”
*Providedforreferenceonly.Alwaysmaintaintheclearances listedtothepipe.
InsertModel
MinimumClearancestocombustiblesmustbemaintainedasshowninthefollowingchart.
NOTE:Materialsprojectingmorethan¾”fromthewallareconsideredmantels.
I J K L M N O P
Q
W3100I 17” 32” 32” 15” 20‐1/2” 4‐9/16” 5‐5/8” 15” 8”
W3100Iw/HeatShield* 16” 24” 18” 15” 20‐1/2” 4‐9/16” 5‐5/8” 15” 8”
*UseontheBreckwellHeatShield–PartNumberCW‐S‐157
Combustible
Trim
ALCOVEINSTALLATION:HeatShieldisREQUIRED
withaminimumof2’Diameter&1”fromCeiling.
DoubleWallPipeisREQUIRED.
OnlyZeroClearanceInstallationsRequire
theBottom2”Clearance
AllInsertInstallationsrequireaminimumof1”
ofk=0.84materialforthehearth.