Operation Manual
SYMPTOM
CAUSE ACTION
Unpleasant
odour.
Odour from the
new pads.
Allow time to
condition by
running the cooler.
Inadequate
cooling.
Dry pads. Ensure the water
supply is turned
on. Then check the
water flow to the
pads.
.
Insufficient
exhaust openings
for conditioned air.
Ensure efficient
openings. Refer to
page 2.
Excessive
ambient humidity.
On days during
the summer when
the ambient
humidity is high,
the cooler will not
reduce the
temperature as
much as on drier
days.
Remote control
has no display.
Batteries are
incorrectly fitted or
they are flat.
R or r the
batteries.
efit eplace
®
18
Evaporative Cooler
Remote control
has flat batteries.
Replace the
batteries.
Fault in the cooler. Contact the Dealer
or Service number.
If the wall or
remote control is in
AUTO or AUTO
TIMER mode and
no fan bars are
displayed the fan
will not come on.
Switch to MANUAL
mode to check the
fan operation.
Cooler turns ON
and OFF.
Fan does not
start but other
functions work.
SYMPTOM
CAUSE ACTION
If your wall control displays SERVICE or should you consider that your
cooler requires service, contact your local Dealer or the Service number on
the back of this manual.
SEELEY INTERNATIONAL – OWNER’S MANUAL 19