User's Manual

RPX ASSEMBLY INSTRUCTIONS
20
Use pump brackets
as template
drill 4 mm holes.
Position the two pumps
at the corner of the tank,
nearest control box.
Secure pumps with
supplied screws.
Ensure pumps leads
are out of water.
Secure pumps leads with
supplied cable ties,
P/No FAS 213.
Fitting the Water Pumps.
SCREW - Phlp.
5x19 mm
P/No 9610013