013109 Multi-Test MT 6 S_2_013109 Multi-Test MT 6_S Bed-Anl. 28.0 Elektronisches Prüfgerät Electronic tester Multi-Test MT 6 S/2 Directions for use ..............................................
013109 Multi-Test MT 6 S_2_013109 Multi-Test MT 6_S Bed-Anl. 28.0 Operating Instructions Important Notice: 1) This testing device is only suitable for use in dry rooms and my not be used for voltages above the specified values. 2) Operate only at ambient temperatures -10°C and +50°C and in the frequency range between 50 and 500 Hz. 3) The sensitivity of the display can be impeded by unfavourable lighting conditions, e.g. strong sunlight or by unfavourable locations, e.g.
013109 Multi-Test MT 6 S_2_013109 Multi-Test MT 6_S Bed-Anl. 28.0 Operating Instructions MT6 S/2 Testing probe Button High intensity LED Screw Open Close ATTENTION: With the exception of the batteries, never attempt to remove any components from the device. Do not use the device if the screw has been removed. Tighten the screw completely (clockwise). Prior to Use Self Test Before each use of the device, a self test must be performed in order to assure correct function.
013109 Multi-Test MT 6 S_2_013109 Multi-Test MT 6_S Bed-Anl. 28.0 MT6 S/2 Operating Instructions (2) touch-free voltage test (100-250 VAC) Hold the tester as shown in the picture and run it slowly along the wire to be tested. If there is alternating current in the wire, the LED will start blinking. If there is a wire break, the LED display will go out. This function can also be used to find alternating current, e.g. in electrical outlets and plugs.
013109 Multi-Test MT 6 S_2_013109 Multi-Test MT 6_S Bed-Anl. 28.0 Operating Instructions MT6 S/2 Flashlight Function Press the button to use the tester as a flashlight. Sample Applications Test the function of lamps and fuses (continuity test) Locating cable breaks (touch-free voltage test) Testing of alternating current (voltage test) Safety symbols = Protection Class II (protective insulation) = Read the operating instructions ATTENTION! = Pay attention to the max. voltage CAT.
013109 Multi-Test MT 6 S_2_013109 Multi-Test MT 6_S Bed-Anl. 28.0 MT6 S/2 Operating Instructions Technical Data: Voltage test 70-250 VAC Touch-free voltage test: a) >=100 VAC (with single insulation) b) 200-250 VAC Polarity test 3-36 VDC Continuity test 0-5 MOhm Disposal Please dispose of your used electronic devices in an environmentally friendly manner! Electronic devices do not belong in your household waste.
013109 Multi-Test MT 6 S_2_013109 Multi-Test MT 6_S Bed-Anl. 28.
Hugo Brennenstuhl GmbH & Co. KG Seestraße 1-3 · 72074 Tübingen · Germany lectra-t Blegistrasse 13 · CH-6340 Baar H. Brennenstuhl S.A.S. F-67460 Souffelweyersheim www.brennenstuhl.com 0451780/311 013109 Multi-Test MT 6 S_2_013109 Multi-Test MT 6_S Bed-Anl. 28.