Installation & Operation Manual Important Information.............................................2 Safety Information..................................................3 Component Identification.......................................3 Specifications.........................................................4 Electrical Requirements.........................................4 Document # 101522 0608 REV A ER 784 Installation..............................................................5 Operation............
IMPORTANT INFORMATION General Remember to read through the entire manual. The features briefly mentioned are just an introduction into the capabilities provided by the AssistPro. This table was specifically engineered to be the most accessible and safest table on the market. Multi-density upholstery, push-only actuators, and numerous on/off switches are just a few of the many touches that make the AssistPRO the best procedure table for every office.
SAFETY INFORMATION Safety Information The primary concern of The Brewer Company is that the equipment is operated and maintained with the safety of the patient and healthcare staff in mind. To ensure safe and reliable operation: • Read and understand all instructions in this manual before attempting to install or operate the unit. • Ensure that appropriate personnel are informed on the manual contents. This is the responsibility of the purchaser.
SPECIFICATIONS Weight of Table......................................................550 lbs. Load Rating (maximum): Seat/Back..............................................................450 lbs. Legrest (Flat & Kneeling).......................................450 lbs. Headrest................................................................100 lbs. Back Section Range................0° (horizontal) to +85° ± 5° Table Top Height Range............19 ± 0.5 in. to 40 ± 1.0 in. Leg Section Range.............
INSTALLATION Overview Perform the following sequence in order when setting up the table: - Uncrating Leveling the Base Installing the Foot Control & Hand Pendant Uncrating NOTE: Inspect all boxes and contents for damage. Report any damage to the carrier immediately. DO NOT lift at these points! CAUTION To avoid damaging the table’s upholstery or painted surfaces, DO NOT use a knife or other sharp object to open the packaging.
INSTALLATION (CONTINUED) Leveling the Table A leveling screw pad (Figure 5) is located in six places under the table’s base. Adjust the six leveling pads to achieve a solid, level installation. Figure 5. Leveling Screw Pad (located under table) Installing the Power Cord 1. Remove the power cord from the shipping box. 2. Insert the plug end of the power cord into the receptacle on the table (Figure 6). Make sure the plug end shape is correctly oriented to the receptacle shape.
INSTALLATION (CONTINUED) Installing the Hand Pendant 1.Remove the hand pendant from the shipping bag Receptacle 2.Insert the plug end of the cord into the hand pendant receptacle on the backrest shroud. See figure 8. 3.Make sure the tab on the cord plug is aligned with the groove in the receptacle and plug is fully seated 4.Thread the locking collar onto the receptacle Hand Pendant Cord 5.
OPERATION General NOTE: For optimum table performance, allow the table to reach room temperature before operating. WARNING If the table malfunctions, immediately remove your hand or foot from the controls, unplug the power cord from the electrical receptacle, and assist the patient from the table. If table continues to malfunction, call for service. Do not attempt to repair table yourself.
OPERATION (CONTINUED) Program Recall #1 Program Set Back Up Program Recall #2 Back Down Stop Program Recall Mode Tilt Up Leg Up Tilt Down Leg Down Program Recall #3 Table Up Table Down Program Recall #4 Figure 10 Controls 1.See figure 10 for the pedal and button identifications on the foot control 2.See figure 11 for the button identifications on the hand pendant WARNING CAUTION The foot control and hand pendant are moisture resistant and run on low voltage.
OPERATION (CONTINUED) Back Up Leg Up Back Down Leg Down TiltUp Table Up Table Down Tilt Down Program Recall #1 Program Recall #2 Program Recall #3 Program Recall #4 Figure 11 Document # 101522 0608 REV A ER 784 10
TABLE ADJUSTMENTS Table Height (Figure 12) The table top can be adjusted to any height between 19” to 40”. 1. To raise the table, depress and hold the Table/Up function until the desired height is achieved. 2. To lower the table, depress and hold the Table/Down function until the desired height is achieved. Table Height Control Figure 12.
TABLE ADJUSTMENTS (CONTINUED) Back Positions (Figure 13) The back can be adjusted to any angle between horizontal and 85°. 1. To adjust the back from a chair (upright) position to a horizontal position, depress and hold the Back/Down function until the desired angle is achieved. 2. To adjust the backrest from a horizontal position to a chair (upright) position, depress and hold the Back/Up function until the desired angle is achieved.
TABLE ADJUSTMENTS (CONTINUED) Legrest Positions (Figure 16) The legrest can be adjusted from a horizontal position to a vertical position. 1. To adjust the legrest from a vertical position to a horizontal position, depress and hold the Legrest/Up function until the desired angle is achieved. 2. To adjust the legrest from a horizontal position to a vertical position, depress and hold the Legrest/Down function until the desired angle is achieved.
TABLE ADJUSTMENTS (CONTINUED) on the foot control will indicate if the “Auto-Run” mode is on or off. To set the program mode using the hand pendant, simultaneously depress the program recall number “3” and number “4” buttons for five seconds until two beeps are heard. 5. When the table is moving in the auto run mode, motion of the table can be stopped by: a. Tapping the “Stop” button on the foot control. b. Tapping any pedal or button on the foot control. c.
TABLE ADJUSTMENTS (CONTINUED) Legrest Extension (Figure 18) In the horizontal position, the legrest can be extended 5” to increase the overall length of the table. CAUTION To prevent damage to the unit, the legrest must be returned to the shortest position prior to lowering the legrest to the vertical position. Lift up on the legrest and pull outward to extend the legrest. To return the legrest to the shortest position, lift up on the legrest and push fully inward. Figure 18.
TABLE ADJUSTMENTS (CONTINUED) Paper Roll (Figure 20) To change a paper roll, insert the paper through the slot in the backrest shrouding and set the paper roll in the holder. Paper Slot Figure 20.
TABLE ADJUSTMENTS (CONTINUED) Stirrups Operating the Stirrups (Figure 21) 1. To operate the stirrups, grasp end of stirrup and pull straight out of the table. Lift up slightly while sliding the stirrup out. NOTE: Do not apply any downward pressure when pulling stirrup from table or it may be difficult to move. This is normal and is part of the stirrup friction locking mechanism 2. Unfold stirrup upward to the fully open position. 3. Adjust the stirrup to the desired length by sliding it in or out.
TABLE ADJUSTMENTS (CONTINUED) Treatment Pan (Figure 24) NOTE: A safety switch prevents upward motion of the legrest when the treatment pan tray is extended. This prevents the legrest from contacting the treatment pan tray. If the legrest upward motion is inoperable, check to ensure that the treatment pan tray is in its fully stowed position (inward). A light clicking sound will be heard just before the treatment pan reaches its fully stowed position. 1.
MAINTENANCE Preventative Maintenance Table Care CAUTION Failure to perform periodic inspections of the table could result in personal injury or equipment damage. • Periodically inspect the electrical cord to ensure it is free of cuts or damage. • Inspect the mechanical functions to ensure satisfactory operation. • Check fasteners to make sure they are present and tightened securely. • Lubricate moving parts (such as back, tilt, and legrest hinges) with a light machine oil.