User's Manual

TM
GE60 Installation Manual
580-00507, rev 1 44 of 46
4.1 Configuring Network Equipment
The networking equipment that is connected to an E60 product should first be checked to
ensure it operates properly over a wired connection. Once this has been confirmed this
will save troubleshooting steps after the radio is installed and connected to the network
equipment.
We strongly recommend the network equipment on both sides of the link be configured
as follows:
- 1000Mbps full-duplex
- No port auto negotiation and no flow control
- Port configured not to enter error-disable state due to link up/down
transitions (since these may occur during periods of heavy rain)
4.2 Check port statistics on the network equipment
In the event the network equipment connected to the GE60 offers the capability below,
we recommend you verify the following on the network equipment:
- Link integrity
- There are no receive errors on the link
- Network traffic is flowing in both directions.