35-DVRS31N Gas Fired Vented Room Heater (Direct Vent) SERIAL NUMBERS 310618 AND HIGHER U6(56¶ INSTALLATION OPERATION and MAINTENANCE MANUAL WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
INTRODUCTION Congratulations on choosing a Brigantia! The 35-DVRS31N is one of the most advanced Direct Vent Gas Fireplace heaters available today. It is solidly designed using the latest technology and manufactured to the highest quality. It is our aim to provide you with an appliance for many trouble-free years of reliable service.
TABLE OF CONTENTS Caution and Safety Instructions 5 Appliance Certification, Installation Codes and Specifications 6 Rating Plate 7 Appliance Dimensions and Framing Dimensions 8-9 Installation Instructions 9-10 Clearance to Combustibles 11 Venting Instructions 11-15 Aeration Adjustment 16 Gas Connections 17 Conversion Kit Instructions 18-19 Final Installation Check and Initial Operation 20 First Fire and
35-DVRS31N 5 CAUTION FOR YOUR SAFETY - Do not install or operate your Brigantia 35-DVRSE31N without reading and understanding this manual. Any installation or operational deviation from this instruction manual voids the Brigantia Industries Warranty and may prove hazardous. This appliance must be installed by a qualified gas installer and the installation must conform to the installation codes.
35-DVRS31N 6 APPLIANCE CERTIFICATION This appliance was listed by LABTEST Certification Inc to the following USA and Canadian gas appliance standards. - ANSI Z21.88-2009/CSA 2.33-2009 Vented Gas Fireplace Heaters - CAN/CGA-2.17-M91, Gas-Fired Appliances for Use at High Altitudes -CSA P.4.1-09 testing method for measuring annual fireplace efficiency.
35-DVRS31N 7 RATING PLATE DO NOT REMOVE THIS LABEL NG / NATURAL LP / PROPANE MODEL / MODÈLE: # de série Serial # LC NE PAS ENLEVER CETTE ÉTIQUETTE 35-DVRS31N LISTED VENTED GAS FIREPLACE HEATER and GAS-FIRED APPLIANCES FOR USE AT HIGH ALTITUDES. RADIATEUR VENTILE, CIRCULATEUR DU TYPE VENTILATEUR. Tested to / Testée selon les normes : ANSI Z21.88-2009 / CSA 2.33-2009 and CAN/CGA-2.
35-DVRS31N APPLIANCE DIMENSIONS 8
35-DVRS31N 9 Framing Dimensions The following section describes in detail the requirements for framing for the model 35-DVRS31N.
35-DVRS31N 10 Installation Instructions Cont. Install the wall inside wall portion of the wall thim- ble and seal the entire inside with a high tempera- ture silicone sealant. This is critical to prevent cold drafts. See figure 4 Seal Install the nailing flanges provide by screwing them to the side of the outer shell using the hole required for the facing material.
35-DVRS31N 11 Nailing Flanges Install the nailing flanges provided, by screwing them to the side of the outer shell using the appropriate holes for the facing material. Place the fireplace into the framed opening and secure the nailing flanges to the wall. Mantle Clearances Clearance to Combustibles Minimum measurements below are from the edge of door (unless otherwise noted).
35-DVRS31N 12 Installation Instructions Outside wall installation example Stand-off 999-DV-HTCL
35-DVRS31N 13 Installation Instructions Cont. VENTING Clearance to combustibles The following clearances must be maintained around the vent pipe: Vertical runs: ´ Horizontal runs: ´ RQ WRS ´ VLGHV DQG ERWWRP IMPORTANT: This appliance venting system is a sealed system (DV), which means that all combus- tion air is supplied from outdoors and the combustion products are exhausted to the outdoors.
35-DVRS31N 14 Installation Instructions Cont. Horizontal Wall Vent Terminations The position of the horizontal vent termination must be positioned in such a way as to meet all local building codes. Attach the correct length of vertical section pipe and an elbow fitting to the stove.
35-DVRS31N 15 Installation Instructions Cont. Vertical Cap Installations $OZD\V PDLQWDLQ D ´ FOHDUDQFH DURXQG WKH YHQW SLSH YHUWLFDO DQG RQ KRUL]RQWDO YHQWLQJ ´ FOHDUDQFH RQ WKH top of the vent, when passing through ceilings, walls, roofs, enclosures, attic rafters or any combustible sur- faces. DO NOT PACK AIR SPACES WITH INSULATION.
35-DVRS31N 16 Installation Instructions Cont. Vent Termination Locations Horizontal Installation G. Do not install above a meter/regulator assembly within 3 7KH KRUL]RQWDO UXQ PXVW KDYH D ´ ULVH RQ DQ H[WHULRU ZDOO DQG feet (90 cm) horizontally from the centerline of the meter/ regulator.
35-DVRS31N 17 Installation Instructions Cont.
35-DVRS31N 18 GAS CONNECTIONS Before connecting the appliance to the gas supply line, double check that the appliance you have purchased is designed for the gas type you are using. The gas type markings are located RQ WKH FHUWLILFDWLRQ ODEHO DQG DOVR RQ WKH DSSOLDQFH¶V JDV YDOYH Adequate clearance for proper installation and checking of the gas connections must be provided. All gas connections must be checked for gas leaks.
35-DVRS31N 19 CHECKING INLET AND OUTLET GAS PRESSURE 1. Remove the surround. 2. The pressure test taps are located on the valve. The taps are located in the gas valve front face. 7KH LQOHW LV PDUNHG µIN¶ DQG WKH RXWOHW LV PDUNHG µOUT¶ See Fig.1. 3. Loosen the set screw inside the tap with a screwdriver. 4. &RQQHFW D ´ PP UXEEHU WXEH WR WKH WDS SRVW DQG D PDQRPHWHU. 5.
35-DVRS31N 20 Contemporary Panels ITEM # PART NUMBER DESCRIPTION QTY.
35-DVRS31N 21 35-DVRS31N Contemporary Panel Installation Instructions Remove burner cover and place to the side to be re-installed at the end. Angle the large contemporary panel (back) into the fireplace. Make sure the 45° cut-out is to the back side of the panel. Push back flat against the fireplace.
35-DVRS31N 22 NOTE: Do not remove any components while the appliance is hot. Door Removal Release the bottom latches located on the left and right bottom of door. To release pull for- ward then press down. Remove the door by pulling the bottom out to 30 de- grees and lift upward to release the 2 latches at the top of the door. CAUTION: Beware the glass does not drop out.
35-DVRS31N 23 FINAL INSTALLATION CHECK Each Brigantia Fireplace is checked and tested at the factory prior to being packaged and shipped to our dealers and finally installed in your home. Archgard recommends that before leaving this unit with the customer, the installer must ensure that the appliance is firing correctly and that the electrical system is in working order. This will include: 1.
35-DVRS31N LIGHTING INSTRUCTIONS ON RATING PLATE 24
35-DVRS31N 25 FIRST FIRE When operated for the first few times, the appliance will emit some odor and fumes. This is due to the heat from the appliance evaporating the oils and solvents used in fabricating the appliance. Close off the room to the rest of the house and open all windows. Keep the room well ventilated, as smoke alarm may sound.
35-DVRS31N REMOTE CONTROL SETUP AND OPERATION 26
35-DVRS31N 27 REMOTE CONTROL SETUP AND OPERATION, cont.
35-DVRS31N REMOTE CONTROL SETUP AND OPERATION, cont.
35-DVRS31N REMOTE CONTROL SETUP AND OPERATION, cont.
35-DVRS31N 30 REMOTE CONTROL SETUP AND OPERATION, cont.
35-DVRS31N 31 REMOTE CONTROL SETUP AND OPERATION, cont. The unit is shipped from the factory with the ability for IPI/CPI selection active. To disable the Continuous Pilot selection ability, cut one of the wires (blue or white) shown in the picture and cap them off to prevent shorting.
35-DVRS31N REMOTE CONTROL SETUP AND OPERATION, cont.
35-DVRS31N 33 MAINTENANCE CAUTION: Do not conduct maintenance on the appliance while it is operating or while it is still hot. CLEANING THE APPLIANCE The exterior painted surfaces, glass and plated trims may be cleaned with a soft, non-abrasive cloth and water or a suitable, mild, non-abrasive cleaner. Regularly: x x x x Frequent cleaning of the ceramic glass is required.
35-DVRS31N 34 CONVERSION KIT INSTRUCTIONS IMPORTANT: This fireplace is Natural gas ready. If converting to LP gas, follow instructions below WARNING: This conversion kit shall be installed by a qualified service agency in accordance with the manufacturers instructions and all applicable codes and requirements of the authority having jurisdiction.
-DVRS31N 35 CONVERSION KIT INSTRUCTIONS CONT.
35-DVRS31N 36 &219(56,21 .,7 ,16758&7,216 FRQ¶W Complete the Conversion Fill out and attach conversion label to the fireplace near the valve Change Rating Plate to show new fuel configuration Reinstall the Burner, burner cover and glass media by reversing the removal process. Turn on the gas and electrical supplies.
35-DVRS31N 37 WIRING SCHEMATICS Synchronization button Main On/Off switch must be connected to the surround VZLWFK DQG LQ WKH ³RQ´ SRVLWLRQ for the remote to operate the fireplace Separate wires to disable CPI activation from remote
35-DVRS31N 38 SERVICING UNDER WARRANTY Before servicing, read the terms and conditions of the Brigantia warranty at the back of the manual. Contact the authorized Brigantia dealer where you purchased the appliance from and provide them with details of the problem, along with the initial installation information (from the front of this manual).
35-DVRS31N 39 REPLACEMENT PARTS LIST Item # 200-0036 Item Description 2ZQHU¶V 0DQXDO Unit EA 308-6011 SIT Pro Flame II Electronic Control Module EA 308-6014 SIT Pro Flame II Handheld Transmitter EA 308-6017 SIT 885 Gas Valve c/w Step Motor EA 308-6012 Module Main Wiring Harness (5 wire) EA 305-0060 Battery Back-up Holder EA 301-0068 Orifice (Main Burner Orifice) Drill to
35-DVRS31N 40 FREQUENTLY ASKED QUESTIONS Listed below are some frequently asked questions regarding Brigantia Gas Fireplaces. If you have questions that are not listed below, or are not answered in this manual, please contact your Authorized Brigantia Dealer. Q. 0\ JODVV KDV D FRQGHQVDWLRQ ³IRJ´ ZKHQ WKH DSSOLDQFH LV ILUVW OLW A. Condensation is normal and will disappear in a few minutes after the glass is heated. Q.
35-DVRS31N NOTES 41
BRIGANTIA LIMITED WARRANTY 7KLV /LPLWHG :DUUDQW\ LV PDGH E\ %5,*$17,$ ),5(3/$&(6 KHUHLQDIWHU UHIHUUHG WR DV ³%ULJDQWLD´ %ULJDQWLD ZDUUDQWV WR WKH RULJinal purchaser of an Brigantia gas burning fireplace (s) that the product will be free of defects in materials and workmanship under normal use DQG VHUYLFH IRU D ³OLIHWLPH´ ,1&/86,216 ³/,)(7,0( /,0,7(' :$55$17<³ ❖ All heat exchangers, combustion chamber, burner tubes and pans.
POSTAGE CUT ALONG LINE WARRANTY REGISTRATION BRIGANTIA FIREPLACES 7116 BEATTY DRIVE MISSION, B.C.
ARCHGARD FIREPLACES 7116 Beatty Drive Mission, B.C. V2V 6B4 Canada Website: www.archgard.