Use and Care Manual

Not for
Reproduction
11
Operation
Generator Capacity
To make sure your generator can supply enough running
watts and starting watts for the items you will power at the
same time, follow these simple steps:
1. Select the items you will power at the same time. See
following list for typical wattages.
* Typical wattages listed are approximate only. Check tool
or appliance for actual wattage.
** Per Briggs & Stratton 628K, Starting Watts represents
the momentary electrical current the generator can
provide to start electric motors. Starting Watts does
not represent the power required to continuously run
electrical loads. Starting Watts is the maximum current
that can momentarily be supplied when starting a motor,
multiplied by the generator’s rated voltage.
2. Total the running watts. This is the amount of power
your generator must produce to keep your items
running. See following example:
Example
Total running watts = 2355
Highest starting watts = 2000
Total generator watts required = 4355
3. Estimate the starting watts you will need. Because not
all motors start at the same time, total starting wattage
can be estimated by adding only the item with the
highest additional starting watts requirements to the
total running watts from step 2.
Power Management
To manage generator power, sequentially add loads as
follows:
1. With nothing connected to generator, start the engine
outdoors.
2. Plug in and turn on the first load, preferably the largest
load you have.
3. Permit the generator output to stabilize (engine runs
smoothly and attached device operates properly).
4. Plug in and turn on the next load.
5. Again, permit the generator to stabilize.
6. Repeat steps 4 and 5 for each additional load.
Never add more loads than the generator capacity. Take
special care to consider surge loads in generator capacity.
Step 5: Generator Shutdown
1. Turn off and unplug all electrical loads from generator
panel receptacles. Never stop engine with electrical
devices plugged in and turned on.
2. Let engine run at no-load for one minute to stabilize
internal temperatures of engine and generator.
3. Push engine switch to off (0) position.
4. Move fuel valve to off (0) position.
Tool or Appliance
Running
Watts*
Starting
Watts
Light Bulb - 75 Watt 75 -
Pump 800 1200
Refrigerator/Freezer 800 2000
Water Pump - 1/3 HP 1000 2000
Air Conditioner- 13,500 BTU 1200 1800
Furnace Fan Blower - 1/2 HP 800 1300
Microwave Oven - 1000 Watt 1000 -
Color Television - 42” 280 -
Personal Computer w/17” monitor 800 -
Tool or Appliance Running Watts Starting Watts
Window air conditioner
1200 1800
Refrigerator 800 2000
Television 280
Light (75 Watts) 75
2355 Total
Running Watts
2000 Highest
Starting Watts