UNIT PREPARATION
Before your engine generator was shipped from our factory it
was fully checked for performance. The generator was load
tested to its full capacity, and the voltage and frequency were
carefully checked and adjusted.
LUBRICATION
Before starting the engine, fill the crankcase to the proper level
with a good quality oil. The recommended grade of oil and
quantity of oil required is listed in the engine operator's
manual shipped with your unit. The necessity of using the
correct oil, and keeping the crankcase full cannot be
overemphasized. Engine failures resulting from inadequate or
improper lubricant are considered abuse and are not covered
by the generator or the engine manufacturer's warranty.
LOW OIL LEVEL SHUTDOWN SYSTEM
This Industrial engine/generator set is equipped with a low oil
pressure shutdown system. This low oil pressure system will
automatically stop the engine when the oil pressure becomes
to low. This feature is designed to reduce costly repairs and
downtime.
CAUTION: EQUIPMENT DAMAGE
Allowing the engine to shutdown repeatedly on
low oil level may cause excessive wear which
can be cumulative.
GASOLINE FUEL
Always use a good grade of unleaded fuel with a minimum of
85 octane. Some fuels, called oxygenated or reformulated
gasoline, are gasoline blended with alcohol or ethers.
Excessive amount of there blends can damage the fuel system
or cause performance problems. If any undesirable operation
symptoms occur, use a gasoline with a lower percentage of
alcohol or ether. DO NOT use gasoline containing
methanol. Always insure that the fuel is clean and free of all
impurities.
INTENDED USES
These engine generator sets have been designed primarily
for portable use. Both 120, 240 and 120/240 volt AC
receptacles are provided in the 'control panel' to plug in your
loads (lights, portable tools, and small appliances). These
units are dual wound generators, therefore the 120 Volt
loads must be equally split between the two power feeds not
to exceed 60 amps on either side. See unit capabilities for
further explanation.
These portable units require large quantities of fresh air for
cooling of both the engine and the generator. Fresh air is
drawn from both the engine end and the generator end and
is exhausted at the center of the unit. For safety, long life
and adequate performance, these units should never be run
inside or in small compartments (such as pickup truck beds)
which can restrict fresh air flow.
RESTRICTED USES
DO NOT remove from the cradle assembly. Removal of the
generator from the cradle assembly may cause excessive
vibration and damage to the engine generator set.
DO NOT install and operate these portable generators in a
small compartment or the bed of a pickup truck. These
compartments will not allow enough free flow fresh air to
reach the engine generator set for cooling and will cause
the unit to overheat, damaging both the engine and the
generator. Small compartments will also develop hot spots
where there is very little air flow and may cause a fire.
DO NOT attempt to operate at 50 cycles. These units are
designed and governed to operate at 60 Cycles only.
UNPACKING
CAUTION: EQUIPMENT DAMAGE
THIS UNIT HAS BEEN SHIPPED WITHOUT OIL.
Failure to maintain the engine oil at the proper level will
result in serious engine damage.
When you unpack your new ENGINE GENERATOR be sure
to remove all the information sheets and manuals from the
carton.
1. This generator set was in good order when shipped.
Inspect the power plant promptly after receiving it. If
damage is noted, notify the transportation company
immediately, request proper procedures for filing a
“concealed damage” claim. Title to the equipment
and responsibility for filing a claim rests with you
when a generator is sent F.O.B. shipping point. Only
you can legally file a claim.
2. Before proceeding with the preparation of your new
engine generator set for operation, take a couple of
minutes to insure that the unit you have received is
the correct model and review the specification pages
in this manual to insure that this unit fits your job
requirements.
3. After removing the engine generator from the carton
locate and remove the shipping strap attached to the
generator shock mount. See attached tag for
removal instructions.