Specifications

2
NOTE: SPECIFICATION TABLES BEGIN ON PAGE 15 OF THIS SECTION.
6
MAGNETRONr IGNITION SYSTEM
Identification
Magnetron has been produced in two versions,
composite Type I (Inset A), Type II (Inset B), and
replaceable module (2), Fig. 11.
NOTE:Magnetron ignition armatures used on
Model Series 120000, 280000 do not have
a visible trigger pole (3) and do not have a
Mylar spacer (1), Fig. 11.
A
B
Fig. 11
1
1
1
2
3
Remove Magnetronr Ignition Armatures
Disconnect Stop Switch Wire
Removal of the flywheel is not required to remove
Magnetron ignition armatures.
1. Remove ignition armature mounting screws.
2. For composite armatures: Disconnect stop switch
wire at spade terminal.
3. For replaceable module armatures: use breaker
point condenser from #294628 point set or a 3/16
inch (4.7 mm) diameter pin punch to release wires
from module, Fig. 12.
4. Unsolder stop switch wire from module wire and
ignition armature primary wire (1), Fig. 12.
Fig. 12
1
Remove Magnetronr Module
1. Remove sealant and/or tape holding ignition
armature wires to ignition armature.
2. Unsolder and separate remaining wires.
NOTE:On some ignition armatures, the module
ground wire must be unsoldered from the
armature ground wire.
3. Move all wires so module will clear ignition
armature and laminations.
4. Lift module retainer (1) and push module off
laminations, Fig. 13.
Fig. 13
1