Specifications

2
NOTE: SPECIFICATION TABLES BEGIN ON PAGE 15 OF THIS SECTION.
10
Stationary Stop Switch, Electrical Check
1. Push down on wire retainer and remove stop
switch wire. On System 2, System 3 and
System 4 engines, the band brake control cover
(2) must be removed, Figs. 26 and 27. If battery
(5) is mounted on the engine, it must be removed
from the battery holder before the cover can be
removed. On series 100700 engines, the flywheel
must be removed before the stop switch can be
tested.
Spark plug wire holding tab (3)
Spark plug (4)
Fig. 26
2. Battery holder bolt (6), connector (7), Fig. 27.
Fig. 26
1
2
3
4
Fig. 27
1
2
5
6
7
WARNING
Disconnect battery before testing.
3. Using Tool #19464, Digital Multimeter, set meter to
ohms () and connect test leads to engine ground
and other test lead to wire retainer. Move control
lever to run position Fig. 24.