Specifications

2
NOTE: SPECIFICATION TABLES BEGIN ON PAGE 15 OF THIS SECTION.
12
5. METAL KEY SWITCH – FIVE OR SIX
TERMINALS: Meter must indicate continuity
between terminals as noted in keyswitch positions
as shown in Fig. 32.
6. SWITCH WITH PLASTIC KEY: Meter should
indicate no continuity with key pushed in, and
continuity with key pulled out.
Fig. 32 B Terminal Positions: Terminal 1 grounded to
switch case. Meter must also indicate continuity
between terminal 1 and switch case.
Switch Position Continuity
1. OFF 1+3+6
2. RUN 2+5+6
3. START 2+4+5
Fig. 32
6
5
4
3
2
1
OFF
3
6
5
4
2
1
RUN
3
6
5
4
2
1
START
OFF
1+3+6
RUN
2+5+6
START
2+4+5