Model / Modelo 030222 (5000W) Owner’s Manual Manual del Propietario Questions? Help is just a moment away! Preguntas? La ayuda es justa un momento lejos! Call: Generator Helpline / Llamada: Generador Helpline 1-800-743-4115 M-F 8-5 CT web: www.briggsandstratton.com CAUTION Before using this product, read this manual and follow all Safety Rules and Operating Instructions. PRECAUCIÓN Antes de utilizar el producto, lea este manual y siga todas las Reglas de Seguridad e Instrucciones de Uso.
PowerBOSS™ SAFETY RULES 5000W Portable Generator SAVE THESE INSTRUCTIONS TABLE OF CONTENTS SAFETY RULES Safety Rules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Assembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-7 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-11 Specifications . . . . . . . . . . . . . . . . . .
SAFETY RULES PowerBOSS™ 5000W Portable Generator WARNING WARNING Running generator gives off carbon monoxide, an odorless, colorless, poison gas. Breathing carbon monoxide will cause nausea, fainting or death. Fuel and its vapors are extremely flammable and explosive. Fire or explosion can cause severe burns or death. • Operate generator ONLY outdoors. WHEN ADDING OR DRAINING FUEL • Turn generator OFF and let it cool at least 2 minutes before removing fuel cap.
PowerBOSS™ 5000W Portable Generator SAFETY RULES CAUTION WARNING Excessively high operating speeds increase risk of injury and damage to generator. Excessively low speeds impose a heavy load. Unintentional sparking can result in fire or electric shock. • DO NOT tamper with governed speed. Generator supplies correct rated frequency and voltage when running at governed speed. • DO NOT modify generator in any way.
FEATURES PowerBOSS™ 5000W Portable Generator KNOW YOUR GENERATOR Read this owner’s manual and safety rules before operating your generator. Compare this illustration with your generator to familiarize yourself with the locations of various controls and adjustments. Save this manual for future reference.
PowerBOSS™ ASSEMBLY 5000W Portable Generator ASSEMBLY • Engine manual • Wheel kit If any parts are missing or damaged, call the generator helpline at 1-800-743-4115. Your generator requires some assembly and is ready for use after it has been properly serviced with the recommended oil and fuel. If you have any problems with the assembly of your generator, please call the generator helpline at 1-800-743-4115.
ASSEMBLY PowerBOSS™ 5000W Portable Generator 6. Retain wheel on axle stud with retaining pin. Install other wheel on remaining axle stud the same way. 7. Attach support leg using two 1/2” or 13mm wrenches with 20mm cap screws and lock nuts. 8. Center lifting handle on generator end of cradle. Attach handle using two 1/2” or 13mm wrenches with 45mm capscrews and hex nuts. Add Fuel NOTE: This gasoline engine is certified to operate on gasoline.
PowerBOSS™ OPERATION 5000W Portable Generator USING THE GENERATOR Generator Location Generator Clearance System Ground WARNING The generator has a system ground that connects the generator frame components to the ground terminals on the AC output receptacles.The system ground is connected to the AC neutral wire (the neutral is bonded to the generator frame). Running generator gives off carbon monoxide, an odorless, colorless, poison gas.
OPERATION OPERATING THE GENERATOR NOTE: If engine starts after 3 pulls but fails to run, or if unit shuts down during operation, make sure unit is on a level surface and check for proper oil level in crankcase. This unit may be equipped with a low oil protection device. See engine manual. CAUTION Exceeding generators wattage/amperage capacity can damage generator and/or electrical devices connected to it. WARNING Running engines produce heat.
PowerBOSS™ 5000W Portable Generator RECEPTACLES OPERATION 120 Volt AC, 15 Amp Duplex Receptacle CAUTION Each of these outlets is protected against overload by a push–to–reset circuit breaker (Figure 6). Receptacles may be marked with rating value greater than generator output capacity. Figure 6 — 120 Volt AC, 15 Amp Duplex Receptacle • NEVER attempt to power a device requiring more amperage than generator or receptacle can supply. • DO NOT overload the generator. See “Don’t Overload Generator”.
OPERATION 5000W Portable Generator DON'T OVERLOAD GENERATOR 4. Plug in and turn on the next load. 5. Again, permit the generator to stabilize. 6. Repeat steps 4 and 5 for each additional load. NEVER add more loads than the generator capacity.Take special care to consider surge loads in generator capacity, as described above. Capacity You must make sure your generator can supply enough rated (running) and surge (starting) watts for the items you will power at the same time. Follow these simple steps: 1.
PowerBOSS™ MAINTENANCE 5000W Portable Generator SPECIFICATIONS Generator Maintenance Maximum Surge Watts . . . . . . . . . . . . . . . . . .6,250 watts Continuous Wattage Capacity . . . . . . . . . . . .5,000 watts Power Factor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.0 Rated Maximum Continuous AC Load Current: At 120 Volts . . . . . . . . . . . . . . . . . . . . . . . . .41.7 Amps Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1–phase Rated Frequency .
STORAGE 5000W Portable Generator STORAGE PowerBOSS™ Engine Storage See engine owner’s manual for instructions. The generator should be started at least once every seven days and allowed to run at least 30 minutes. If this cannot be done and you must store the unit for more than 30 days, use the following guidelines to prepare it for storage. Other Storage Tips • To prevent gum from forming in fuel system or on essential carburetor parts, add fuel stabilizer into fuel tank and fill with fresh fuel.
PowerBOSS™ TROUBLESHOOTING 5000W Portable Generator TROUBLESHOOTING Problem Cause Correction 1. One of the circuit breakers is open. 1. Reset circuit breaker. 2. Fault in generator. 2. Contact Authorized service facility. 3. Poor connection or defective cord 3. set. Check and repair. 4. Connected device is bad. 4. Connect another device that is in good condition. Generator runs good at no-load but "bogs" down" when loads are connected. 1. Short circuit in a connected load. 1.
BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC EQUIPMENT OWNER WARRANTY POLICY Effective September 1, 2004 replaces all undated Warranties and all Warranties dated before September 1, 2004 LIMITED WARRANTY Briggs & Stratton Power Products Group, LLC will repair or replace, free of charge, any part(s) of the equipment that is defective in material or workmanship or both. Transportation charges on parts submitted for repair or replacement under this warranty must be borne by purchaser.
PowerBOSS™ REGLAS DE SEGURIDAD 5000 Watt Generador Portátil CONSERVE ESTAS INSTRUCCIONES TABLA DE CONTENIDOS REGLAS DE SEGURIDAD Reglas De Seguridad . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16-18 Características . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Montaje . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20-21 Operación . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
REGLAS DE SEGURIDAD PowerBOSS™ 5000 Watt Generador Portátil ADVERTENCIA ADVERTENCIA Al generador funcionar, se produce monóxido de carbono, un gas inodoro y venenoso. El respirar el monóxido de carbono, producirá náusea, desmayo o la muerte. La combustible y sus vapores son extremadamente inflamables y explosivos. El fuego o una explosión pueden causar quemaduras severas e inclusive la muerte. • Opere el generador SOLAMENTE al aire libre.
PowerBOSS™ 5000 Watt Generador Portátil REGLAS DE SEGURIDAD PRECAUCIÓN ADVERTENCIA Las velocidades de operación en exceso, aumentan los riesgos de heridas y daños al generador. Las velocidades bajan en exceso, imponen una carga muy pesada. Chispear involuntario puede tener como resultado el fuego o el golpe eléctrico. CUANDO AJUSTE O HAGA REPARACIONES A SU GENERADOR • NO cambie ninguna velocidad determinada.
CARACTERÍSTICAS 5000 Watt Generador Portátil PowerBOSS™ CONOZCA SU GENERADOR LEA ESTE MANUAL DEL PROPIETARIO Y LAS REGLAS DE SEGURIDAD ANTES DE OPERAR SU GENERADOR. Compare las ilustraciones con su Generador para familiarizarse con las ubicaciones de los diferentes controles y ajustes. Conserve este manual para referencias futuras.
PowerBOSS™ MONTAJE 5000 Watt Generador Portátil MONTAJE • Manual del Propietario Su generador requiere de ciertos procedimientos de montaje y solo estará listo para ser utilizado después de haberle suministrado servicio con el combustible y aceite recomendados. • Manual del Motor • Juego de Ruedas Si cualquier parte falta o está dañada, llame a la Línea de Ayuda del Generador al 1-800-743-4115.
MONTAJE Agregue Combustible NOTA: Está seguro instalar la rueda con inboard levantado de eje. 5. La unidad de la punta e instala la rueda. Coloque arandela plana sobre semental de eje. 6. Retenga la rueda en el eje llena de alfiler que retiene. Instale otra rueda en el túnel restante de eje la misma manera. 7. Conecte el pierna de apoyo usa dos 1/2” o 13 mm llaves inglesas con un 20 mm tornillo de la tapa y nuez de cerradura. 8. Centre el asidero que levanta en el fin del generador de cuna.
PowerBOSS™ OPERACIÓN 5000 Watt Generador Portátil USO DEL GENERADOR Ubicación del Generador Espacio Libre Alrededor del Generador Tierra del Sistema ADVERTENCIA El generador dispone de una conexión a tierra del sistema que conecta los componentes del bastidor a los terminales de tierra de los enchufes hembra de salida de CA. La tierra del sistema está conectada al cable de CA neutro que, a su vez, está conectado al bastidor del generador (vea “Descripión del Equipo”).
OPERACIÓN PowerBOSS™ 5000 Watt Generador Portátil OPERANDO EL GENERADOR PRECAUCIÓN NOTA: Si el motor arranca después de tirar tres veces del arrancador pero no sigue funcionando, o si la unidad se para en funcionamiento, asegúrese de que la unidad está en una superficie plana y compruebe que el nivel de aceite del cigüeñal es correcto. La unidad puede equiparse con un dispositivo de protección de bajo nivel de aceite.
PowerBOSS™ 5000 Watt Generador Portátil RECEPTÁCULOS PRECAUCIÓN OPERACIÓN 120 Voltios AC, 15 Amperios, Receptáculos Dobles Cada receptáculo (Figura 13) está protegido en contra de sobrecargas por un corto-circuitos de, del tipo "empuje para reposicionar". El valor nominal que se indica en los enchufes hembra puede ser superior a la capacidad de salida del generador. • NUNCA intente suministrar corriente a un dispositivo de amperaje superior al que puede suministrar el generador o el enchufe hembra.
OPERACIÓN NO SOBRECARGUE GENERADOR 4. 5. 6. Conecte y encienda la próxima carga. De nuevo, permita que el generador se estabilice. Repita los pasos 4 y 5 para cada carga adicional que usted tenga. NUNCA añada más cargas sobre la capacidad del generador. Tome una atención especial en considerar las cargas de corriente según la capacidad del generador, como se describe arriba.
PowerBOSS™ 5000 Watt Generador Portátil MANTENIMIENTO NOTA: NO recomendamos el uso de mangueras de jardín para limpiar el generador. El agua podría introducirse en el sistema de combustible del motor y causar problemas. Además, si el agua se introduce al generador a través de las ranuras para aire de enfriamiento, algo del agua quedará retenida en los espacios vacíos y grietas del aislamiento del devanado del estator y rotor.
ALMACENAMIENTO PowerBOSS™ 5000 Watt Generador Portátil ALMACENAMIENTO Almacenando el Motor El generador deberá ser encendido al menos una vez cada siete días y deberá dejarlo funcionar al menos durante 30 minutos. Si no puede hacer esto y debe almacenar la unidad por más de 30 días, siga las siguientes instrucciones para preparar su unidad para almacenamiento. Consulte el manual del propietario del motor para las instrucciones de cómo preparar adecuadamente el motor para su almacenamiento.
POLÍTICA DE GARANTÍA PARA EL PROPIETARIO DE EQUIPOS BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC Fecha de entrada en vigor: 1 de Septiembre de 2004. Sustituye a todas las garantías sin fecha y a las de fecha anterior al 1 de Septiembre de 2004 GARANTÍA LIMITADA Briggs & Stratton Power Products Group, LLC reparará o sustituirá sin cargo alguno cualquier componente del equipo que presente defectos de materiales y/o mano de obra.