6200 Watt Portable Generator Operator’s Manual BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC JEFFERSON, WISCONSIN, U.S.A. Printed in U.S.A. Manual No.
Thank you for purchasing this quality-built Briggs & Stratton generator. We are pleased that you’ve placed your confidence in the Briggs & Stratton brand. When operated and maintained according to the instructions in this manual, your Briggs & Stratton generator will provide many years of dependable service. This manual contains safety information to make you aware of the hazards and risks associated with generator products and how to avoid them.
Table of Contents Operator Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Equipment Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Safety Rules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Unpack Generator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operator Safety Hazard Symbols and Meanings Equipment Description Read this manual carefully and become familiar with your generator. Know its applications, its limitations and any hazards involved. The generator is an engine–driven, revolving field, alternating current (AC) generator. It was designed to supply electrical power for operating compatible electrical lighting, appliances, tools and motor loads. The generator’s revolving field is driven at about 3,600 rpm by a single-cylinder engine.
WARNING The engine exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm. WARNING Generator produces hazardous voltage. Failure to isolate generator from power utility can result in death or injury to electric utility workers due to backfeed of electrical energy. • When using generator for backup power, notify utility company. Use approved transfer equipment to isolate generator from electric utility.
WARNING Contact with muffler area can result in serious burns. Exhaust heat/gases can ignite combustibles, structures or damage fuel tank causing a fire. • DO NOT touch hot parts and AVOID hot exhaust gases. • Allow equipment to cool before touching. • Keep at least 5 feet (1.5 m) of clearance on all sides of generator including overhead.
Assembly Install the wheel kit as follows: 1. Tip generator so that engine end is up. 2. Slide axle (A) through both mounting brackets. 3. Place a wheel (B) on each side as shown below. 4. Place a washer (C) on axle and then place an e-ring (D) in axle groove. Your generator requires some assembly and is ready for use after it has been properly serviced with the recommended fuel and oil. If you have any problems with the assembly of your generator, please call the generator helpline at (800) 743-4115.
Add Engine Oil 1. Place generator on a flat, level surface. 2. Clean area around oil fill and remove yellow oil fill cap. NOTE: See the section Oil to review oil recommendations. Verify provided oil bottle is correct viscosity for current ambient temperature. 3. Using oil funnel (optional), slowly pour contents of provided oil bottle into oil fill opening. 1. Clean area around fuel fill cap, remove cap. 2. Slowly add unleaded gasoline (A) to fuel tank (B). Be careful not to overfill. Allow about 1.
5. Verify that connections to battery and generator are tight and secure. NOTE: Charge prior to use following the instructions in the section Battery Float Charger. System Ground The generator has a system ground that connects the generator frame components to the ground terminals on the AC output receptacles. The system ground is connected to the AC neutral wire (the neutral is bonded to the generator frame).
Features and Controls Read this Operator’s Manual and safety rules before operating your generator. Compare the illustrations with your generator, to familiarize yourself with the locations of various controls and adjustments. Save this manual for future reference. A J H B C D E F G A - Fuel Tank — Capacity of seven (7) U.S. gallons (26.5 L).
Cord Sets and Receptacles Use only high quality, well-insulated, grounded extension cords with the generator’s 120 Volt duplex receptacle. Inspect extension cords before each use. Check the ratings of all extension cords before you use them. Extension cord sets used should be rated for 125 Volt AC loads at 20 Amps or greater for most electrical devices. Some devices, however, may not require this type of extension cord. Check the operator’s manuals of those devices for the manufacturer’s recommendations.
Battery Float Charger Use battery float charger jack to keep the starting battery charged and ready for use. Battery charging should be done in a dry location, such as inside a garage. 1. Plug charger into unit’s “Battery Float Charger” jack, which is located next to the start switch. Plug battery charger into a 120 Volt AC wall receptacle. 12 2. Unplug charger from unit and wall outlet when generator is being started and while it is in operation. 3.
Operation Starting the Engine IMPORTANT: Always unplug the battery float charger before starting the generator. Disconnect all electrical loads from the generator. Use the following start instructions: 1. Make sure unit is on a level surface. IMPORTANT: Failure to start and operate the unit on a level surface will cause the unit not to start or shut down during operation. 2. Turn the fuel valve to the “On” position. The fuel valve handle should be vertical (pointing toward the ground) for fuel to flow. 5B.
Connecting Electrical Loads 1. Let engine stabilize and warm up for a few minutes after starting. 2. Plug in and turn on the desired 120 and/or 240 Volt AC, single phase, 60 Hz electrical loads. NOTE: • DO NOT connect 240 Volt loads to the 120 Volt duplex receptacles. • DO NOT connect 3-phase loads to the generator. • DO NOT connect 50 Hz loads to the generator. • DO NOT OVERLOAD THE GENERATOR. See Don’t Overload Generator. NOTICE Stopping the Engine 1.
Don’t Overload Generator Capacity You must make sure your generator can supply enough rated (running) and surge (starting) watts for the items you will power at the same time. Follow these simple steps: 1. Select the items you will power at the same time. 2. Total the rated (running) watts of these items. This is the amount of power your generator must produce to keep your items running. See Wattage Reference Guide. 3. Estimate how many surge (starting) watts you will need.
Maintenance Maintenance Schedule Follow the hourly or calendar intervals, whichever occurs first. More frequent service is required when operating in adverse conditions noted below.
NOTICE Improper treatment of generator can damage it and shorten its life. • DO NOT expose generator to excessive moisture, dust, dirt, or corrosive vapors. • DO NOT insert any objects through cooling slots. • Use a soft bristle brush to loosen caked on dirt or oil. • Use a vacuum cleaner to pick up loose dirt and debris. Battery Maintenance Other than float charging, described elsewhere, no maintenance is required for the starting battery. Keep the battery and terminals clean and dry.
3. Clean area around oil drain plug (A). The oil drain plug is located at base of engine, opposite carburetor. C A B 4. Remove oil drain plug and drain oil completely into a suitable container. 5. Reinstall oil drain plug and tighten securely. Remove oil fill cap. 6. Slowly pour oil (about 28 oz.) into oil fill opening (B) to the point of overflowing (C) at oil fill cap. DO NOT overfill. 7. Reinstall oil fill cap. Finger tighten cap securely. 8. Wipe up any spilled oil.
1. To remove muffler heat shield (A) from muffler (B), remove four screws that connect guard to muffler bracket. C A B Check Valve Clearance Regular valve clearance check and adjustment will improve performance and extend engine life. This procedure cannot be done without partial engine disassembly and the use of special tools.
Storage The generator should be started at least once every seven days and allowed to run at least 30 minutes. If this cannot be done and you must store the unit for more than 30 days, use the following guidelines to prepare it for storage. Generator Storage • Clean the generator as outlined in Cleaning. • Check that cooling air slots and openings on generator are open and unobstructed. Long Term Storage Instructions Fuel can become stale when stored over 30 days.
Troubleshooting Problem Engine is running, but no AC output is available. Engine runs good at no-load but “bogs down” when loads are connected. Engine will not start; or starts and runs rough. Cause 1. 2. 3. 4. 1. Short circuit in a connected load. 2. Engine speed is too slow. 3. Generator is overloaded. Reset circuit breaker. Contact authorized service facility. Check and repair. Connect another device that is in good condition. 4. Shorted generator circuit. 1. 2. 3. 4. 5. 1. 2. 3. 4. 5.
Warranties Emissions Control System Warranty Briggs & Stratton Corporation (B&S), the California Air Resources Board (CARB) and the United States Environmental Protection Agency (U.S. EPA) Emissions Control System Warranty Statement (Owner’s Defect Warranty Rights and Obligations) California, United States and Canada Emissions Control Defects Warranty Statement The California Air Resources Board (CARB), U.S.
2. Length of Coverage B&S warrants to the initial owner and each subsequent purchaser that the Warranted Parts shall be free from defects in materials and workmanship which caused the failure of the Warranted Parts for a period of two years from the date the engine is delivered to a retail purchaser. 3.
BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC PORTABLE GENERATOR OWNER WARRANTY POLICY Effective February 1, 2006 replaces all undated Warranties and all Warranties dated before February 1, 2006 LIMITED WARRANTY Briggs & Stratton Power Products Group, LLC will repair or replace, free of charge, any part(s) of the portable generator that is defective in material or workmanship or both. Transportation charges on product submitted for repair or replacement under this warranty must be borne by purchaser.
Portable Generator Product Specifications Starting Wattage . . . . . . . . . . . . . . . . . . . . . . . .8,750 watts Wattage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6,200 watts AC Load Current: at 120 Volts . . . . . . . . . . . . . . . . . . . . . . . . . . .51.6 Amps at 240 Volts . . . . . . . . . . . . . . . . . . . . . . . . . . .25.8 Amps Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Single phase Rated Frequency . . . . . . . . . . . . . . . . . . . . . . . . .