User Manual
BL-PRO-MIX- 8*8/18*18/32*32 
Accidental damage: Please send back to the manufacturer for repair. 
7. Communication protocol and control instruction code 
Communication protocol: (Baud rate 115200, data bits 8, stop bit 1, no parity bit)  
Type 
Control 
instruction 
Functional description 
Opera
ting 
instruc
tions 
aXb.take. 
Switch a channel input to b channel output 
aX1-b.take. 
Switch a channel input to 1-b channel output 
aXb1,b2,b3.take. 
Switch a channel input to b1,b2,b3 channel output 
a1Xb1.a2Xb2.a3
Xb3.take. 
Switch a1,a2,a3 channels input to corresponding 
b1,b2,b3 channels output 
Save[Y]. 
Save current scene to [Y], [Y] means number keys 
from 1 to8 
Recall[Y]. 
Recall the input/output switching saved in [Y], [Y] 
means number keys from 1 to 8 
Buzzer on. 
Turn on buzzer 
Buzzer off. 
Turn off buzzer 
Remarks: 
1. “a” represents input , “b” represents output. The subscript "1", "2", "3" in the 
instruction are not input characters.   
Numerical range of a and b is decided according to the matrix type. For example, 
BRIGHTLINK PRO-MIX32*32 matrix has up to 32 input/output channels. Any 
channel out of range of 1-32 would be regarded as an input error. 
2. Do not forget the last punctuation (“.”). Every instruction ends with the punctuation 
“.” . Punctuations are all English character punctuations. 
3.  Pay  attention  to  the  letter  case.  (Save/Recall/Buzzer:  These  3  words  should  be 
capitalized.) 
7.1 Code Examples 
 1. Input “1X2.take.” to switch No. 1 channel input to No. 2 channel output. 