User guide

5
IV. Dimensions
Dimensions of heat pumps (monoblock-type) for swimming pools
V. Preparations for installation
5.1 Selection of the installation position
The heat pump has to be installed in a spacious and well ventilated place.
Its position has to guarantee adequate free space for the exhaust (the location of the air inlet is shown
in the diagram on the next page).
• The heat pump has to be situated close to a drain or vent so as to make water discharge easier.
• The installation base or brace has to be rm enough to ensure smooth operation of the device.
• Make sure the device, when installed, is situated vertically, without any inclination.
• Do not install the device in places where there is contamination, corrosive gas or where dirt or fallen
leaves accumulate.
The heat pump must not be installed in the vicinity of an in ammable or explosive environment or
near things that are a common cause of re.
Maintain the distances from obstacles as indicated with arrows in the picture below.
THP 55 THP 100 THP 120
L 1000 1090 1090
W 360 370 370
H 550 612 612
E 818484
F 200 270 270
Unit: mm
Dimension
Model
THP 170
L 1165
W 470
H 685
A 440
B
760
F 325
G 81,5
Unit: mm
Dimension
Model
EN