User guide
5
IV. Dimensions
Dimensions of heat pumps (monoblock-type) for swimming pools
V. Preparations for installation
5.1 Selection of the installation position
• The heat pump has to be installed in a spacious and well ventilated place.
• Its position has to guarantee adequate free space for the exhaust (the location of the air inlet is shown
in the diagram on the next page).
• The heat pump has to be situated close to a drain or vent so as to make water discharge easier.
• The installation base or brace has to be fi rm enough to ensure smooth operation of the device.
• Make sure the device, when installed, is situated vertically, without any inclination.
• Do not install the device in places where there is contamination, corrosive gas or where dirt or fallen
leaves accumulate.
• The heat pump must not be installed in the vicinity of an infl ammable or explosive environment or
near things that are a common cause of fi re.
• Maintain the distances from obstacles as indicated with arrows in the picture below.
THP 55 THP 100 THP 120
L 1000 1090 1090
W 360 370 370
H 550 612 612
E 818484
F 200 270 270
Unit: mm
Dimension
Model
THP 170
L 1165
W 470
H 685
A 440
B
760
F 325
G 81,5
Unit: mm
Dimension
Model
EN