EN POOL EQUIPMENT KLIN GOTHIC ITC DEMI-13,3 b zlatá černá PANTONE 871 U Swimming Pool Heat Pump XHP PANTONE 426 U INSTALLATION AND USER GUIDE i Read the instructions Illustrative photo
EN Contents POOL EQUIPMENT KLIN GOTHIC ITC DEMI-13,3 b 1. Specification...............................................................................................................................................3 2. Performance curves.....................................................................................................................................4 3. Dimensions............................................................................................................................
EN 1. Specification 1.1 Horizontal heat pump, coolant R410A, ONLY HEATING POOL EQUIPMENT KLIN GOTHIC ITC DEMI-13,3 b Models XHP 40 XHP 60 XHP 100 XHP 140 XHP 200 3.5 5.0 9.0 12.0 18.0 0.80 1.44 1.92 2.88 6.25 6.25 6.25 6.25 6.25 220−240 V 220−240 V 220−240 V 220−240 V 220−240 V Nominal current (A) 2.8 4.1 6.7 9.3 13.9 Recommended fuse (A) 10 10 20 20 35 0−15 0−20 25−40 35−60 60−90 Recommended water flow (m3/hr) 4.2 4.2 6 8.4 10.
EN 2.
EN 3. Dimensions POOL EQUIPMENT KLIN GOTHIC ITC DEMI-13,3 b Models zlatá černá PANTONE 871 U PANTONEXHP 42640U XHP 60 XHP 100 XHP 140 XHP 200 A 273 330 330 380 B 423 680 655 650 C 260 280 300 360 D 293 360 350 410 E 747 930 1,000 1,000 F 210 230 340 560 G 83 83 83 83 H 470 520 590 820 Unit: mm 4. Installation 4.
EN Discharge connection POOL EQUIPMENT KLIN GOTHIC ITC DEMI-13,3 b BYPASS to the swimming pool from the filter valve 1 zlatá černá PANTONE 871 U PANTONE 426 U valve 2 valve 3 from to heat pump NOTE: The manufacturer delivers only the heat pump system. Other items shown in the illustration are other necessary components of the water system provided by users or suppliers.
EN ATTENTION: Please follow the steps below to put the heat pump into operation for the first time: 1. Open the valves to let water into the system. 2. Make sure there is no water leaking in the connections. 3. Run the heat pump with the circulating pump in operation. POOL EQUIPMENT KLIN GOTHIC ITC DEMI-13,3 b zlatá PANTONE 871 U 4.2 Selection of the installation position černá PANTONE 426 U • It is recommended to install the heat pump in a sunny, spacious and well ventilated place.
EN • The swimming pool heat pump is usually installed near the swimming pump at a maximum distance of 7.5 metres. If installed beyond this limit, the technology system (pipes) can cause higher heat losses. POOL EQUIPMENT Most pipes are installed underground, and although the technology system (pipes) must be provided with KLIN GOTHIC ITC DEMI-13,3 b thermal insulation, all tunnels and surrounding soil will still receive the heat, unless the ground is wet or the water level is high.
EN 5. Electrical connection 5.1 Connection diagram for the swimming pool heat pump POOL EQUIPMENT KLIN GOTHIC ITC DEMI-13,3 b XHP 40, XHP 60, XHP 100 red orange IMPORTANT: The installation and connection of this device to the power supply can only be provided by a person that has the electrical qualifications in accordance with Decree No. 50/1978 Coll.
EN 5.2 Connection diagram for the swimming pool heat pump XHP 140 red orange POOL EQUIPMENT KLIN GOTHIC ITC DEMI-13,3 b zlatá černá Fan motor te whi Electric expansion valve red PANTONE 871 U PANTONE 426 U black black yellow/green Compressor yellow/green white blue blue brown OUTPUT1 OUTPUT2 Four-way valve RUN/ POWER SUPPLY blue OUTPUT3 GND GND red GND OUTPUT4 GND GND GND Transformer GND GND GND GND blue GND yellow blue GND red OUTPUT5 brown A.C.
EN 5.3 Connection diagram for the swimming pool heat pump XHP 200 POOL EQUIPMENT KLIN GOTHIC ITC DEMI-13,3 b Four-way valveblue orange yellow /green Fan motor Starting capacitor black white blue A.C.
EN NOTE: 1. The above mentioned connection diagrams are for information only; please use the diagrams delivered POOL EQUIPMENT together with the device. KLIN GOTHIC ITC DEMI-13,3 b 2. The swimming pool heat pump has to be well earthed, although the heat exchanger unit is electrically insulated from the rest of the unit. In spite of that, it is still necessary to earth the unit to protect yourself against short-circuits inside the unit.
EN Time delay: The heat pump is equipped with a built-in 3-minute protection against restart. Time delay control is an integral part of the control circuit, which limits restart cycles and contactor clicking. POOL EQUIPMENT KLIN GOTHIC ITC DEMI-13,3 b Time delay automatically restarts the heat pump approximately 3 minutes after each interruption of the control circuit.
EN 7. Setting operating data POOL EQUIPMENT KLIN GOTHIC ITC DEMI-13,3 b 7.1 Heating only operation 7.2 Control display functions 1. up and down arrows zlatá 2. timer on button černá PANTONE 871 U PANTONE 426 U 7 3. timer off button 4. clock button 5. on/off button 1 6 1 6. operating mode display 5 7. LED display 2 3 4 7.
POOL EQUIPMENT KLIN GOTHIC ITC DEMI-13,3 b EN Parameter 0 setting the temperature for the incoming water in cooling mode 8 to 35°C, (default setting is 28°C) zlatá černá Parameter 1 setting the temperature for the incoming water in heating mode 15 to 40°C, (default setting is 28°C) Parameter 2 total operating time for the compressor after defrosting 30 to 90 minutes, (default setting is 40 minutes) PANTONE 871 U PANTONE 426 U Parameter 3 conditions for activating the defrosting function -30 to 0°C, (
EN POOL EQUIPMENT KLIN GOTHIC ITC DEMI-13,3 b Parameter 9 heat target for super performance -15 to 15°C, (default setting 10°C) zlatá černá Parameter A manual setting of the interval for the electronic expansion valve 18 to 94, (default setting 70 (*5)) PANTONE 871 U PANTONE 426 U 7.
EN POOL EQUIPMENT KLIN GOTHIC ITC DEMI-13,3 b Parameter H: current intervals of the electronic expansion valve zlatá černá PANTONE 871 U PANTONE 426 U NOTE: 1. press the up or down arrow to check the temperature of incoming water, temperature of outgoing water, capacitor temperature, temperature of returned gas, ambient temperature, current intervals of the electronic expansion valve 2.
EN 7.5 Setting the water temperature In the current mode, press the up or down arrows to set the water temperature, even if the heat pump is off. POOL EQUIPMENT KLIN GOTHIC ITC DEMI-13,3 b 7.6 Setting the locking function Press the up and down arrow simultaneously to lock the setting. To unlock the setting, press the arrows again zlatá PANTONE 871 U simultaneously. černá PANTONE 426 U 7.7 Setting the clock Press the button to set the clock and use the up and down arrows to select the values.
EN ATTENTION: • It is necessary to check the heat pump operation parameters after the installation and before the first use. • When the heat pump is running, the LED display shows the temperature of incoming water. • If you switch off the heat pump using the On/Off button on the control LED display, thus putting the heat pump into the STANDBY mode, the LED display will show the clock. • The water temperature may be adjusted when the heat pump is running.
EN 8. Troubleshooting 8.1 Error codes shown on the controller with LED display POOL EQUIPMENT KLIN GOTHIC ITC DEMI-13,3 b Fault Cable controller Cause Solution Defect to the temperature sensor for incoming water PP1 The sensor is either open or short-circuited. Check or replace the sensor. The sensor is either open or short-circuited. Check or replace the sensor.
EN 8.2 Other faults and solutions (with no display on the controller with LED) POOL EQUIPMENT Fault KLIN GOTHIC ITC DEMI-13,3 b The heat pump is not working zlatá černá There is a drop in water temperature when the pump is running in the heating mode. Display Cause Solution The LED display shows nothing. No power supply Check the connection of the cable and the circuit breaker. The LED display shows the current time. The heat pump is in the standby mode. Start up the heat pump.
EN 9.
EN 10.
EN 10. Spare parts 2 POOL EQUIPMENT KLIN GOTHIC ITC DEMI-13,3 b manometer zlatá černá high pressure valve fan motor capacitor PANTONE 871 U PANTONE 426 U low pressure valve temperature sensors control unit 11.
EN 12. Replacement of parts POOL EQUIPMENT KLIN GOTHIC ITC DEMI-13,3 b Filter zlatá černá Low pressure valve Electronic expansion valve PANTONE 871 U High pressure valve PANTONE 426 U Suction valve Manometer Important warning: The components of the heat pump can only be replaced and repaired by a specialized company or an authorized service centre. Do not attempt to remove any defects yourself. There is a risk of electrical accident or other hazards.
EN Warranty terms and conditions The warranty conditions are governed by your supplier’s trade and warranty terms and conditions. POOL EQUIPMENT KLIN GOTHIC ITC DEMI-13,3 b Safe disposal of the product after its service life After its service life is over, have the product disposed of ecologically by a specialized company. Claims and servicing Claims are governed by applicable consumer protection legislation. In the event a fault cannot be rectified, please contactzlatá your supplier in writing.
POOL EQUIPMENT KLIN GOTHIC ITC DEMI-13,3 b zlatá černá PANTONE 871 U PANTONE 426 U