User Manual
Brillian 
AI 2000 CIDRW 
12 
11:47:25.109: Send ENQ. 
11:47:25.140: Receive EOT. 
11:47:25.140: Send a Block.(10960740) 
12 00 00 92 01 80 01 00 A7 3F  64 01 02 41 02 30 31 01 00 03 
06 
11:47:25.171: Receive ACK. 
11:47:25.171: Send S18F1(10960740). 
S18F1 W 
<L[2] 
<A[2] "01"> 
<L[0] 
> 
> 
. 
S18F2 example: 
11:47:25.171: Receive ENQ. 
11:47:25.171: Send EOT. 
11:47:25.328: Received a Block (10960740). 
78 80 00 12 02 
80 01 00 A7 
3F 
64 
01 04 41 02 30 30 41 02 4E 
4F 01 0C 41 01 31 41 01 30 41 
04 49 
44 4C 45 
41 04 31 
2E 
35 
36 41 07 42 
52 
39 32 30 30 77 
41 08 42 52 49 4C 4C 49 41 4E 
41 04 49 44 
4C 45 41 02 30 30 
41 
0F 
45 50 2D 
33 30 32 
31 31 
31 20 56 65 72 
3A 
42 41 04 
39 
36 30 30 
41 02 31 36 41 01 30 
01 04 41 02 
4E 45 
41 01 30 
41 
04 49 44 
4C 45 41 04 49 44 4C 
45 18 4B 
11:47:25.328: Send ACK. 
11:47:25.328: Receive S18F2(10960740). 
S18F2 
<L[4] 
<A[2] "00"> 
<A[2] "NO"> 
<L[12] 
<A[1] "1"> 
<A[1] "0"> 
<A[4] "IDLE"> 
<A[4] "1.56"> 
<A[7] "BR9200w"> 
<A[8] "BRILLIAN"> 
<A[4] "IDLE"> 
<A[2] "00"> 
<A[15] "EP-302111 Ver:B"> 
<A[4] "9600"> 
<A[2] "16"> 
<A[1] "0"> 
> 
<L[4] 
<A[2] "NE"> 
<A[1] "0"> 
<A[4] "IDLE"> 
<A[4] "IDLE"> 
> 
> 