User Manual
Brillian
AI 2000 CIDRW
20
S18F11 example:
12:04:23.937: Send ENQ.
12:04:23.968: Receive EOT.
12:04:23.968: Send a Block.(10960750)
1B 00 00 92 0B 80 01 00 A7 3F 6E 01 02 41 02 30 31 41 09 4E
46 46 30 30 35 30 33 32 05 67
12:04:24.031: Receive ACK.
12:04:24.031: Send S18F11(10960750).
S18F11 W
<L[2]
<A[2] "01">
<A[9] "NFF005032">
>
.
S18F12 example:
12:04:24.875: Receive ENQ.
12:04:24.890: Send EOT.
12:04:24.953: Received a Block (10960750).
29 80 00 12 0C 80
01 00 A7 3F
6E
01
03
41
02
30
31
41
02 4E
4F 01 04 41 02 4E
45 41 01 30
41 04 49 44 4C 45 41 04 49 44
4C 45 08 0E
12:04:24.953: Send ACK.
12:04:24.953: Receive S18F12(10960750).
S18F12
<L[3]
<A[2] "01">
<A[2] "NO">
<L[4]
<A[2] "NE">
<A[1] "0">
<A[4] "IDLE">
<A[4] "IDLE">
>
>
.
4.8
S18F71 Event Report Send(ERS) H←E
data structure:
L,4
<TargetID>
<SSACK>
<CEID> =>message ID
L,n
<DVNAME1> =>message name
<DVVAL1> =>message value
…
<DVNAMEn>
<DVVALn>
explanation:This message send from CIDRW,during Remote I/O button71