Standalone N2 Purge System Operation Manual Ver 1.0 Version STD AD100 Manufacturer and publisher Brillian Network & Automation Integrated System Co.,Ltd Add: No.41, Keyi St., Zhunan Township, Miaoli County 350, Taiwan, R.O.C. Tel: 886-37-580708 Fax: 886-37-580728 Email:services@brillian.com.tw Website:http://www.brillian.com.
Contents 1 2 3 4 5 6 7 8 9 Brief introduction of equipment ................................................................................................ - 1 Description of safety rule of STD AD100 .................................................................................. - 2 Description of starting steps ..................................................................................................... - 3 Description of stopping steps ..........................................................
1 Brief introduction of equipment Brillian Material Handling Solution(BMHS) We provide a FAB semi-automatic material handling solution. Through a material storage devices, integrating the BMHS system and database, product locations and determine the transmission route, optimal throughput and increase productivity. eRack management collects all eRack status information, exchanges information on behalf of all eRacks and MES. Provides admin search queries, work order inquiries, statistical analysis, etc.
2 Description of safety rule of STD AD100 2.1 Instruction for use。 2.1.1 This manual is only written for Purge System Module。 2.1.2 Non-qualified or non-professional personnel are not allowed to operate or maintain the machine。 2.1.3 “Operator” should read carefully the software operation in advance。 2.1.4 “Maintainer”, in addition to getting familiar with software operation, should read carefully the maintenance manual and circuit diagram。 2.1.
1. 2. 3 Description of starting steps 3.1 Adapter to be AC 100~230V 4 Description of stopping steps 4.1 Please remove Adapter 5 Facility Requirement&SPEC When power is supplied, non-professional personnel should not operate it to avoid electric shock hazard. Before checking, maintenance and repair, please turn off the power. Product Name Standalone N2 Purge System Model Type STD AD100 Rating(Adapter) 100~230VAC, 50/60Hz, 1ɸ+PE Length X Width X Height(mm) kg Frequency 134.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.
STD AD100 Module Illustration Front-1 -5- Brillian Network & Automation Integrated System Co., Ltd.
-6- Brillian Network & Automation Integrated System Co., Ltd.
8 STD AD100 Hardware 8.1 Hardware Method Power Switch Breaker Power Spully AC110~230V FUSE BR I/O PCB Digital Board Inlet Valve*2 Outlet Valve*2 Clamp Valve RH/Temp Sensor Analogy Board Inlet Pressure*2 Outlet Pressure*2 Flow Meter MFC 9 Operation Description Put a FOUP fixed on the goods which you need to get goods information.
Periodical Maintenance 10.1 Cleaning Plate 10.1.1Purpose:Cleaning Plate Particle Material:NA Manual tool:Cleanroom wiper、DI Water Notice:Before action, please confirm whether the machine is down PM Step:Cleanroom wiper cloth into the DI Water from inside to outside and from top to clean the Plate surface. -8- Brillian Network & Automation Integrated System Co., Ltd.
-9- Brillian Network & Automation Integrated System Co., Ltd.