Installation Guide
9
HOSE AND REGULATOR:
Your grill is equipped with a Type 1 connection device with the following features:
1.  The system will not allow gas  ow from the cylinder until a positive connection to the valve has been made.
 Note:  The cylinder valve and all grill burner knobs must be turned OFF before any connection is made or 
removed.
2.  A regulator  ow limiting device, when activated, restricts the  ow of gas to 10 cubic feet per hour. If the 
 ow limiting device is activated, perform Regulator Resetting Procedure. 
  Note:  If your grill will not get hot enough to cook, the  ow limiting device may have been activated.
CONNECTING HOSE AND REGULATOR:
1.  Inspect the propane tank valve rubber seal for cracks, wear or 
deterioration prior to use. A damaged rubber seal can cause a gas 
leak, possibly resulting in an explosion,  re or severe bodily harm. Do 
not use a propane tank with a damaged rubber seal.
2.  Attach or detach regulator to the LP gas cylinder only when cylinder is 
at rest in tank holder. 
3.  Check that the cylinder valve is closed by turning the knob clockwise.
4.  Check that the grill’s burner control knobs are in the “OFF” positions.
5.  Visually inspect the hose assembly prior to each use for evidence of damage, excess wear, or 
deterioration. If found, replace the assembly before using your grill. Only the manufacturer’s supplied 
replacement should be used.
6.  Remove the protective plastic cap from the cylinder valve.
7.  Check that the hose does not contain kinks, does not contact sharp edges, and does not contact 
surfaces that may become hot during use.
8.  Hold regulator and insert the brass nipple into the LP cylinder valve outlet. Ensure that the device is 
centered properly.
9.  Turn the large coupling nut clockwise by hand and tighten to a full stop. Take care not to cross thread 
the coupling nut onto the cylinder valve. Do not use tools to tighten connection.
  Note:  If you are unable to make the connection, repeat Steps 7 and 8.
10. Leak check all  ttings before lighting your grill. See section on “Leak Testing” in this manual.
REGULATOR RESETTING PROCEDURE:
If your grill will not get hot enough to cook, the  ow limiting device may have been activated.
Mini Reset:
  Turn ALL burner control knobs to “OFF”, turn off the cylinder valve. Wait one minute. Slowly turn 
cylinder valve ON and relight grill. If burner  ame is higher and grill heats up properly – proceed with 
cooking.
Full Reset:
  Turn ALL burner control knobs to “OFF”, turn off the cylinder valve. Disconnect hose and regulator from 
cylinder. Wait two minutes, reattach hose and regulator and perform leak test.
WARNING
•  Never use your grill without leak testing all gas connections, hoses and propane tank. Follow 
the section on “Leak Testing” in this manual for proper procedures.
LEAK TESTING:
Inspect Rubber Seal (see page 8)