Use and Care Manual
1) Turn o the cold water supply to the sink.
2) Turn on the kitchen faucet to release pressure and allow water to drain from the line.
3) Disconnect the cold water line from the threaded stem on the bottom of the kitchen
faucet. Attach threaded ends of supplied brass tee to the cold water supply line and
shut-o valve; tighten using an adjustable wrench.
4) Attach 1/4” tube to the tee:
5) Do not connect the other end at this time.
INSTALL TEE FITTING
MAIN WATER SUPPLY
RISER TUBE
Push the tubing into the quick connect tting, then gently pull back on the tubing
to make sure the connection was secure.
To Disconnect: Push in and hold down on the collet ring square against the tting.
With the collet held in this position the tube can be removed.
CONNECTING THE SYSTEM
How to Connect: - Push the tubing into the qui ck connect fitting, then gently pull ba ck
on the tubing to make sure the connection was secure.
- No inserts, sleeve, or nuts are needed to secure the connection.
- No Teflon tape!
To Disconnect: - Push in and hold down on the collet ring square against the fitting.
With the collet held in this position the tube can be removed.
I: Tee to Connection Port Labeled “IN”
II: Tee to Connection Port Labeled “OUT”
Take the tubing leading from the tee and insert it into
the manifold port indicated by the label “IN”. Remember
to push it all the way until it stops.
Take the tubing leading from the tee and insert it into
the manifold port indicated by the label “OUT”. Remember
to push it all the way until it stops.