® Centipede 2 Module System Instructions Centipede 2® Module Temperature Control System With 4.3” Touchscreen Display (C2MOD-OI) Instruction Manual 1055 Gibbard Ave, Columbus, OH 43201 Toll Free: 800-848-7673 Phone: 614-294-3376 Fax: 614-294-3807 Email: bhtsales1@briskheat.com Read and understand this material before operating or servicing these heating tapes. Failure to understand how to safely operate these heaters could result in an accident causing serious injury or death.
® ® Centipede 2 Module System Instructions Table of Contents Centipede 2 Module System Instructions Warranty Important Safety Instructions ................................................................ 3 Introduction ............................................................................................. 4 General Specifications ......................................................................... 4 Quick Start Guide ..........................................................................
® ® Centipede 2 Module System Instructions Appendix 4: Troubleshooting Guide Please read this guide prior to contacting BriskHeat. This guide is designed to answer the most commonly asked questions. If you are unable to identify the problem or need additional assistance, please contact us at 1-800-848-7673 (U.S. / Canada), 1-614-294-3376 (worldwide), or bhtsales1@briskheat.com. PROBLEM SOLUTION(S) Heater does not warm up Verify heater is connected to proper voltage.
® ® Centipede 2 Module System Instructions INTRODUCTION Your Centipede 2® Temperature Control System supplies a complete network of temperature control by providing a controller and sensor to EACH heater in a system. A Centipede 2® Module Unit is a compact PID temperature controller with RTD feedback. Multiple modules can be networked together with CAT5 communication cables. The Centipede 2® Touchscreen Interface Unit acts as a Modbus master for up to 128 Centipede 2® Modules.
® ® Centipede 2 Module System Instructions Centipede 2 Module System Instructions QUICK START GUIDE Appendix 1: Fuse Replacement Fuse should be replaced with properly rated fuse: 2 AMP @ 240VAC max. Do not replace fuse with live power applied to Centipede 2®. Only authorized personnel should replace fuse. 1. Remove power from unit. 2. Replace the blown fuse with a new one of the specified amperage. 3. Apply power to unit. 4.
® ® Centipede 2 Module System Instructions Centipede 2 Module System Instructions INSTALLATION Alarm Toggles Connecting C2MOD-C Modules to Heaters 1. Connect the 6-pin connector from the heating jacket to the C2MOD-C unit. This connector provides the control power and RTD temperature sensor input. Defines which errors are displayed on the operator interface. The only parameter that can be toggled OFF is the Lo Temp. 2. Plug in the CAT-5 connectors on each side of the module.
® ® Centipede 2 Module System Instructions Alarm Setup Centipede 2 Module System Instructions Understanding the Centipede 2® Touchscreen Interface (C2MOD-OI) User can set-up alarm contacts to remain in alarm position and heaters powered off until the user manually clears the alarm. F Getting There A Main Menu Global Program Reset Default Setting B C D Alarm Latch Set-up Touch the Latch parameter to toggle ON/OFF. See page 14 for definitions.
® ® Centipede 2 Module System Instructions Centipede 2 Module System Instructions Touchscreen Interface Mounting Instructions C2MOD-OI comes equipped with four 4-40 mounting screws and nuts for easy installation. Cut out a panel using the illustrations below. Example of Screenshot when Password Mode is Enabled The user would need to enter a password to log-in to enter all edit menus. See Enter Password below to log-in.
® ® Centipede 2 Module System Instructions Password Management Centipede 2 Module System Instructions Operating the C2MOD-C Module This menu: Understanding the Status LED 1. Allows a user to set-up password protect mode 2. Or log-in into admin mode (if password mode is enabled) to edit settings. Each Centipede 2® Module provides basic status of your heater system with its LED light found on the front.
® ® Centipede 2 Module System Instructions Understanding the Operator Interface Status LED ® The Centipede 2 Operator Interface’s Status LED provides basic status of the entire Centipede 2® Module Network. Green: All the modules in the network are within their temperature limits and no errors exist. Blinking Red: One or more of the modules in the network have errors. Solid Red: No modules are connected to the operator interface.
® ® Centipede 2 Module System Instructions Centipede 2 Module System Instructions Change System Date and Time: VIEW SYSTEM NOTE: This function is used for time and date stamping of the error log. View performance and settings of each zone. 1. Touch the Date / Clock field. The below menu appears. Multi-Zone View Navigation B F A G E D 2. 3. Use the + and – buttons to change date and time. Touch the Exit icon when complete. Touch in General Options menu to save changes.
® ® Centipede 2 Module System Instructions Centipede 2 Module System Instructions Change Operator Interface Name Single-Zone View Touch any zone in the Multi-Zone view to go to the detailed Single-Zone View C B 1. Touch the O/I Name field. A keyboard screen appears. 2. Input the desired Operator Interface name (maximum 12 character D E H A F G A.
® ® Centipede 2 Module System Instructions General Options Centipede 2 Module System Instructions Understanding the Status Codes Getting There Main Menu Global Program Reset Default Setting Status Message Description OK No alarms present. Current actual temperature is above high alarm limit. Current temperature is below the low alarm limit. RTD is shorted. RTD is open. Internal module communication error. Communication between module and operator interface is lost. Zone is disabled (Turned Off).
® ® Centipede 2 Module System Instructions Edit a Single Zone OPTIONS / SETUP Basic Navigation Touch the desired field to program. See below for detailed instructions. Centipede 2 Module System Instructions Saves parameters to selected module. Exits out of Single Zone edit menu without saving. Returns to Single Zone view. A. General: General Options. Set O/I name, scroll rate, and date/time. See page 21. B. Network: Modbus settings. See page 24. C. Password Management: See page 25. D.
® ® Centipede 2 Module System Instructions Reset Default Settings Centipede 2 Module System Instructions GLOBAL PROGRAMMING Getting There Main Menu Global Program Reset Default Setting Select one of the three choices: A. Global program ALL MODULES in a system B. Global program BY OUTPUT STRING (1 – 4) C. Reset to Default Settings NOTE: To determine which string you want to program, trace the CAT 5E communication cable to the Touchscreen Interface. They are numbered from string 1 to 4.
® ® Centipede 2 Module System Instructions Global Programming Parameters Centipede 2 Module System Instructions Programming Low Alarm, Set Point, and High Alarm: 1. Touch the desired field. A numeric keyboard screen appears. 2. Input the desired temperature (0 to 325°C). Touch Basic Navigation Touch the desired field to program. See below for detailed instructions. complete. Saves parameters to selected modules. Returns to Main when exits back to Global Programming menu. Menu. 3.