Instruction manual

BriskHeat
®
Corporation. All rights reserved
22
Centipede 2
®
Module System
Instructions
Change System Date and Time:
NOTE: This function is used for time and date stamping of the error log.
1. Touch the Date / Clock field. The below menu appears.
2. Use the + and – buttons to change date and time. Touch the Exit icon
when complete.
3. Touch in General Options menu to save changes.
Change Clock View:
1. Toggle between 24 HR and 12 HR clock by pressing button next to
Time in General Options menu view.
2. Touch to save changes.
Touchscreen Calibration:
1. Touch in General Options menu.
2. Touch Screen to continue to Calibration.
3. Touch Screen 3 times at each arrow (repeat for 3 arrows).
4. Touch screen to finalize calibration.
BriskHeat
®
Corporation. All rights reserved
11
Centipede 2
®
Module System
Instructions
VIEW SYSTEM
View performance and settings of each zone.
Multi-Zone View Navigation
D
F
A
B
C
G
E
A. Multi-Zone Display (10 zones at one time)
Str: String number
Zone: Zone number
Temp: Actual temperature in °C
Green color: OK status mode
Red color: Error status mode. Status message provided in Single-
Zone view.
Touch any zone in the Multi-Zone View to go to the Single-Zone View.
B. Changes Multi-Zone view by String number: ALL, 1, 2, 3, or 4.
C. Home button: To Main Menu screen
D. Left navigation: View last 10 zones
E. Right navigation: View next 10 zones
F. Quick navigation: Jump ahead 10, 20, or 30 zones at one time
G. Scroll button:
Activates automatic scroll of zones
Pauses automatic scroll of zones
See page 22 for how to adjust scroll rate