Product Manual

Full-Coverage Drum Heater (FGDH & FGPDH Series)
© BriskHeat
®
Corporation. All rights reserved. © BriskHeat
®
Corporation. All rights reserved.
Full-Coverage Drum Heater (FGDH & FGPDH Series)
INSTALLATION / OPERATION INSTRUCTIONS
Read and understand this entire
manual before operating this drum
heater
VOLTAGE:
120VAC; 240VAC
SPECIFICATIONS
4 5
Adjustable On / Off Digital Controller
50-450ºF (10-232ºC) for FGDH series
50-160ºF (10-71ºC) for FGPDH series
120 or 240 Volts Models
Power cord 6’ (2m) long Patented grounded heating element
450ºF (232ºC) maximum exposure temperature
on heating surface
Dielectric strength over 2000 volts
Heated area for FGDH series is the lower third
Heated area for FGPDH series is the lower two
thirds
Intended for use in dry environments. Do not
expose to spray.
STEP 1
Remove heater from box. Make visual inspection of heater. Do not use
if torn or damaged.
STEP 2
Drum heater should be placed on a clean, dry surface. Open hook and
loop closure like VELCRO
®
on heater and position around drum with
adjustable thermoswitch in the upper third of the heater. Heater should
be positioned on drum such that it is covering the drum from the oor
to the top of the drum. Fasten hook and loop closure so heater is tight
against the drum with no sagging or bundling. Cover top of drum with
optional insulation cover (sold separately, PN: FGDC55). For larger
diameter drums, up to 24.2” (615mm), optional Insulated expansion
strips are available (sold separetly, PN: FGDHSTRIP).
STEP 3 (see page 3 for electrical compliance)
For 120VAC model, plug standard 3-prong plug to appropriate
electrical power supply. For 240VAC model, terminate power cord
to appropriate electrical power supply. The power cable consists of
three color-coded conductors, black, white, and green. The black wire
should be connected to Line 1. The white wire should be connected
to Line 2. The green wire should be connected to earth ground. The
power connections must be adequately rated to electrially support the
voltage and amperage of the heater. The identi cation label located on
the power cord displays voltage and amperage requirements. Follow
all local electrical codes for proper electrical connections.
STEP 4
Adjust controller to desired setting (See page 6 for programming
instructions). Drum heaters designed for metal drums (FGDH series)
can be adjusted 50-450ºF (10-232ºC). Drum heaters designed for
plastic drums (FGPDH series) can be adjusted 50-160ºF (10-71ºC).