Full-Coverage Drum Heater (FGDH & FGPDH Series)
TROUBLESHOOTING GUIDE
Please read this guide prior to contacting BriskHeat
®
. This guide is designed to
answer the most commonly asked questions. If you are unable to identify the
problem or need additional assistance, please contact your
local distributor/ representative or us at 1-800-848-7673, 614-294-3376, or
bhtsales1@briskheat.com.
6
PROBLEM SOLUTION(S)
Does not heat Verify heater is connected to proper voltage. The
identi cation label located on the power cord displays
the heater’s voltage requirement.
Check to see if there is a resistance reading (not an
open circuit) in heater using an ohm meter.
Circuit breaker is tripping Validate that the circuit breaker is capable of handling
the amp requirement of heater. The identi cation
label located on the power cord displays the heater’s
amperage requirement.
Examine heater and cord for any damage.
Does not t Con rm that the heater provided was designed to t
around your speci ed drum.
If the heater was designed for the speci ed drum,
please call 1-800-848-7673 or 614-294-3376 for further
assistance.
Something has lightly spilled on exterior
or interior
To remove spillage from heater surface use any typical
household cleaner, that does not contain any silicone
rubber dissolving type ingredients, with a clean cloth.
7
PARAMETER PROGRAMMING
Set Point (SP) is the only parameter the user can access without code
protection.
• Press SET. SP text will appear on the display.
• Press SET again. The real value is shown on the display.
• The value can be modi ed with the UP and DOWN arrows.
• Press SET to enter any new values.
• Press SET and DOWN at the same time to quit
programming or wait one minute and the display will automatically exit
programming mode.
BUZZER
In the event of alarm or error condition, the internal buzzer is activated. To
silence the buzzer, press and hold the SET and Down keys for 2 seconds.
LED INDICATIONS
OUT This indicates that the heater is on.
DISPLAY MESSAGES
In normal operation, the sensor temperature will be shown on the display. In
case of alarm or error, the following messages will be shown:
• Er = Memory Error
• -- = Short-Circuit Probe Error (Disconnects output).
• oo = Open Probe Error (Disconnects output).
CONTROLLER OPERATION:
Once the controller reaches set point, the heater will turn off and will not turn on
again until the temperature falls 5°F below the set point.
The controller will alarm if the temperature at the sensor exceeds 15°F of the
setpoint.
PROGRAMMING DIGITAL TEMPERATURE CONTROLLER