Product Manual

SRL-ADJ & SRP-ADJ Series Instructions
BriskHeat
®
Corporation. All rights reserved
5
MOUNTING YOUR HEATING BLANKET
Your heater can be attached to the surface using:
- Factory applied PSA (pressure sensitive adhesive)
- Factory supplied mechanical fasteners
- High-temperature adhesive tape that will not damage the heater
- Thin layer of RTV
For all installations, regardless of adhesion method:
1. Ensure heater is in contact with the surface to be heated. If air gaps are
present, heat transfer will decrease and there is a potential to overheat
the heating blanket. Use a medium to hard roller to eliminate trapped
pockets of air.
2. Do not crease the heater, wrap over itself or allow contact with a second
heater.
Installation of heater using factory supplied Pressure Sensitive Adhesive
(PSA):
Peel off the release film [
Figure A on next page
] and then press the heater onto
the surface of the item being heated using a medium to hard rubber roller [
Figure
B
on next page]. Ensure blanket is making intimate contact with the surface to be
heated.
- The pressure sensitive adhesive will cure when the blanket is energized
and heat is generated. PSA generally cures in twenty minutes at 200ºF
(93ºC) in a 68ºF (20ºC) ambient environment. The cure time will vary
with temperature of the blanket and surrounding ambient conditions. The
higher the ambient temperature and set-point of the blanket, the faster
the cure time.
- The blanket may require a temporary method of attachment to secure
the heater until the PSA cures. Use a high-temperature adhesive tape
(BriskHeat
®
Part # AAT2180) to secure the heater.
- For larger heaters, press the heater onto the surface as the film is
removed.
NOTE:
BriskHeat
®
does not recommend allowing pressure sensitive adhesive to
cure at temperatures below 40ºF (4ºC).
SRL-ADJ & SRP-ADJ Series Instructions
6
BriskHeat
®
Corporation. All rights reserved
Figure A: Removing Film Figure B: Rolling the Blanket
CONNECTING HEATER TO AC POWER
- The heater is designed to operate at a specific voltage: Refer to the lead
wire label or stamp located on the heater for rated voltage and wattage. Failure
to operate the heater at its rated voltage could cause damage to the heater,
surface being heated, or contents.
- All electrical connections must be made by qualified personnel and in
accordance with all local codes and regulations.
- Properly sized circuit breakers must be used. The end-user is responsible
for providing suitable electrical protection device. It is highly recommended that a
ground fault circuit breaker be used.
- If heater is equipped with a plug:
Plug power cord into appropriate receptacle.
- If heater is
not
equipped with a plug:
Two wires (same color) should be connected to the power source directly,
through a junction box, or to a connector that is mated to a receptacle connected
to the power source. BriskHeat
®
SRL-ADJ/SRP-ADJ Silicone Rubber Heating
Blankets with Control are non-polarized, allowing either wire to be connected to
the neutral or hot. The third wire, designated by the color green (or a green
stripe), should be connected to ground.
Removable
Film
Surface
Blanket
Surface
Blanket
Roller