Operation Manual

34
Program Overview
ID-Information
ÀÀÀ
00 Current level
ÀÀÀ
-1 History level 1
ÀÀÀ
-2 History level 2
ÀÀÀ
-3 History level 3
ÀÀÀ
-4 History level 4
ÀÀÀ
E1 Error inlet metre
ÀÀÀ
E2 Error drainage metre
Carbonate hardness
set of 2 sec.
ÀÀÀ
Device type set of 2 sec.
ÀÀÀ
RESET set of 2 sec.
ÀÀÀ
Parameter acceptance
ÀÀÀ
Month limit set of 2 sec.
ÀÀÀ
Hardness type set of 2 sec.
Operating mode
ParameterisationRetrieval mode
1 x button Press button 4 seconds
30 sec.no activity =
no Parameter acceptance
20 sec. no activity
Carbonate hardness • Capac-
ity • By-pass • last fi lter
change date
10 Troubleshooting
10.1 No water fl ow
10.1.1 Cause: Water intake closed.
Troubleshooting: Open water intake on the upstream stop valve or inlet valve on inlet hose.
10.1.2 Cause: Confused inlet and outlet installation.
Troubleshooting: Check and, if necessary, correct the assembly situation (Chapter 4.3) of the intake
hose
6
with intake valve
7
and terminal device connection
8
with fl ush valve
9
. Pay attention to
the direction of fl ow according to the arrows on the connector head
4
.
10.1.3 Cause: Non-return valve in the entrance to the connector head not seated correctly.
Troubleshooting: Check direction of fl ow as in Chapter 10.1.2 and seat of the non-return valve and
correct if necessary (Chapter 4.3). Flush fi lter system again (Chapter 5.4).
!
Caution: The following faults may be remedied only by trained and authorised personnel.
10.2 No or low water fl ow in spite of open water intake
Cause: Mains pressure too low.
Troubleshooting: Check mains pressure. If the fault continues, check the fi lter system and fi lter car-
tridge and change if necessary.
!
Caution: Prior to changing, read the Technical Data (Chapter 11) and the Operating and Safety
Information (Chapter 3).