Operation Manual

35
Total hardness
measured
By-pass setting
PURITY 600
Quell GY
PURITY 1200
Quell GY
By-pass setting
PURITY 600
Quell GY
PURITY 1200
Quell GY
with fl ow heater without fl ow heater
°dH % %
22 10 2178 4034 0 2000 3705
23 10 2083 3858 0 1913 3543
24 10 1996 3698 0 1833 3396
25 10 1916 3550 0 1760 3260
26 10 1843 3413 0 1692 3135
27 10 1774 3287 0 1630 3019
28 10 1711 3169 0 1571 2911
29 10 1652 3060 0 1517 2810
30 10 1597 2958 0 1467 2717
31 10 1546 2863 0 1419 2629
32 10 1497 2773 0 1375 2547
33 10 1452 2689 0 1333 2470
34 10 1409 2610 0 1294 2397
35 10 1369 2536 0 1257 2329
8 Repair
Regularly check the fi lter system for leaks. Regularly check the hoses for kinks. Bent hoses must be
replaced.
The complete fi lter system must be replaced in rotation after a maximum of ten years.
The hoses must be replaced in rotation after a maximum of fi ve years.
!
Caution: Prior to changing, read the Technical Data (Chapter 12) and the Operating and Safety
Information (Chapter 3).
Regularly clean the outside of the fi lter system with a soft, damp cloth.
!
Caution: Do not use any substances incompatible with the material (Chapter 3.4) or abrasive
cleaning materials.
9 Query Mode
The following data can be queried in the query mode:
Production data
Briefl y press button 1 x (< 1 second), the following message appears.
Serial Appliance Number Battery Service Life
ID Level Production Year
Production year: Example 08 = 2008
Device number: consecutive
Battery useful life: Example 31/12/19 = The battery in the display unit will be exhausted on 31/12/19
and the complete fi lter system has reached its max. usage period.