User Manual
16 ENGLISH
8 Technical data of the A 1000 cartridge
Operating pressure 0.1 MPa to max. 0.86 MPa
Water intake temperature 4°C to 30°C
Ambient tem-
perature during
operation 4°C to 40°C
storage/transport –20°C to 50°C
Working fl ow range and associated
pressure loss
30–180 L/h /
0.02–0.14 MPa
Bed Volume 0.23 L
Weight (dry/wet) 0.4 kg/0.9 kg
Chlorine reduction NSF 42 Class I (50 %)
Particle retention NSF 42 Class I (0.5 µm)
Chlorine reduction DIN EN 14898 Class 1 (>90 %)
Dimensions
(Width/Depth/
Height)
Filter system (fi lter
head with fi lter car-
tridge)
106 mm/92 mm/232 mm
Filter cartridge 86 mm/86 mm/224 mm
Installed dimensions
(vertical installation
with wall mounting)
137 mm/122 mm/232 mm
Operating position Horizontal and vertical
Water inlet connection G3/8"
Water outlet connection G3/8"
8.1 Technical data of the BRITA Tap
Operating pressure 0.05 MPa to max. 1 MPa
cold water connection 4°C to 40°C
warm water connection max. 70°C
Water Rating 6 stars (4.5 L/min)
Weight
Dimensions
(Width/Depth/
Height)
Aerator
WD 3010 1.16 kg
5 cm / 25.5 cm /
19.1 cm
M18x1
WD 3020 1.52 kg
17.3 cm / 28.4 cm /
29.4 cm
M24x1
WD 3030 1.45 kg
17.2 cm / 20.5 cm /
36.3 cm
M22x1
WD 3040 1.57 kg
17.2 cm / 23.7 cm /
34.8 cm
M22x1