User Manual
8 ENGLISH
Screw the M8 connector of the hose with the blue stripe into the
hole C.
Screw the M8 connector of the hose with the red stripe into the
hole H.
Screw the M8 connector of the 800 mm hose into the hole B.
C
B
H
(fi g. 7)
WD 3010
WD 3020/ WD 3030/ WD 3040
C
BH
!
Ensure the connections are screwed tight, but avoid over-
tightening.
Then place the base (3) over the hole and fi x the BRITA Tap (1) in
position using the supplied counter plate (4), the washer (5), the
locking ring (6) and the hexagon nut (7).
3.4 Step 4: Attaching the hoses
!
The supplied hose for connection to the cold water supply
requires the availability of an already installed ½" isolation
or angle valve). Before installation, please ensure you have
such a free ½" isolation or angle valve and that it is work-
ing properly (closeable to 100 %). If not, please contact
a licensed plumber. In accordance with regulations, the
stopcock) which is included in your kit must be installed at
the point of connection to the water supply before the fi lter
system intake hose. Behind the stopcock or isolation valve
a pressure limited valve must always be installed to ensure
the right function of the cartridge. Plumbing tape should
be used on all threads in this sub-assembly and tested to
ensure there are no leaks.
We recommend that you fi rst arrange all parts you need in front of
you.
Recommended tools for installation: one Allen key and an adjust-
able spanner.
Recommended for installation of the wall mount bracket: two
screws (e.g. 5 mm in size suited to the mounting surface) and two
wall plugs (if necessary).
Please follow the diagram below (see fi g. 7) and perform the steps
in the right order.
A Connect supplied T-piece on your cold water supply
a) Insert one 1/2" washer into the female nut of the supplied
T-piece.
b) Connect this end of the t-piece to your cold water supply.
!
If you do have an additional free 1/2" cold water supply for
the BRITA Tap in your kitchen, you do not need to install the
supplied T-piece.
B Connect the hose with the blue stripe to one side of the T-piece
or free ½” cold water supply using washer supplied.
C Take the hose with two 1/2" connectors. Insert the 1/2" washers
into the respective female threads of the two hose ends. Con-
nect one end with the free side of the T-Piece.
D Now connect the other end to the fi lter head inlet. This is labelled
“IN” and marked with an arrow. Make sure that the washers are
seated correctly!
E Connect the 800 mm hose to the “OUT” (connection point on
fi lter head) which labelled with an out arrow.
F Connect the hose with the red stripe with your hot water supply
G Make sure all connections are tightened properly. Avoid over
tightening.