Installation manual

Revision F • 3/11
HARRIS CORPORATION
3-21
3 Control Center Software
Preferences Window
low the USB flash drive to be recognized by
Windows.
7. Click
Install
. In the pop-up window, select
the USB flash drive as the destination. The
ECC app will now unzip and copy the firm-
ware code update files to the USB flash drive.
8. Once the updated files are copied from the
PC to the USB flash drive, right click on
“Safely Remove Hardware” in the Windows
system tray and select the USB device (for
example: “Safely remove USB Mass Storage
Device”). Remove the USB flash drive from
the PC’s USB port.
9. Insert the USB flash drive back into the USB
port on the rear panel of the HDE-200.
10.
The HD Radio signal encoding will be in-
terrupted when you perform the next step
,
so you must ramp out of the Diversity
Delay and the optional Profanity Delay. You
can do this using ECC or from the front panel
buttons on the HDE-200.
11. Once the Diversity and Profanity Delays are
both at 0.0 seconds (0% ramp), reset the
HDE-200 by pressing the rear panel re-
cessed button: RESET PROCESSOR. The
HD Radio signal will be interrupted but the
non-delayed analog audio continues through
the HDE-200 during this process.
It takes about four minutes for the HDE-
200 to update the code (ATTN: KEEP
POWER ON is displayed during the update
process) and restart (a normal STARTUP
message is displayed during this time).
12. When the normal display returns, Ramp Up
the Diversity Delay and, if applicable, the
Profanity Delay.
13. Remove the USB flash drive.
3.5.5.8 Preferences
Click
System > Preferences...
to open the
HDE-
200 Control Center Preferences
pop-up window
which shows which IP address the computer is
using to communicate with the FlexStar LAN, the
Multicast IP address, and Multicast port used to
receive community Multicast messages.
If there is only one network connection on the
computer, then its IP address will be shown in the
FlexStar Network Interface entry box. If there are
two or more NICs in the computer, click on the
down arrow to select the IP address for the NIC
connected to the FlexStar network.
If this setting is not set to the NIC connected to
the FlexStar devices then the ECC app will not
see the HDE-200. Thus, this window is the first
place to look if you cannot establish a connection
to the HDE-200.
NOTE: To ensure proper Multicast
monitoring by ECC, the FlexStar Mul-
ticast settings should be set to their
defaults: 239.255.255.1, port 50010.
When the ECC app is first installed, the Win-
dows Users and Groups security settings are NOT
applied to the app, allowing for easy configura-
tion of the ECC app and the HDE-200 Exporters.
But, once the ECC app and the HDE-200s are
configured, click Enable Security to activate the