Installation manual

Revision F • 3/12
HARRIS CORPORATION
5-10
5 Service
7. Click
Next
to open the
Select Installation
Folder
window. For best results, use the de-
fault file location. Before continuing, set the
program access. Select
Everyone
so that mul-
tiple users can log into the computer and
use ECC. Continue the installation by click-
ing
Next
on this and the following screen.
Once the installation completes, click
Close
to close the installer window.
8. The ECC program automatically leaves the
four Windows user groups as they were from
the previous version of the program. If new
users need to be added or others removed,
follow the instructions on page 3-3 to set
user access to the ECC program’s features.
NOTE: The ECC program requires
Microsoft .NET Framework Version
2.0 Service pack 1. It can be down-
loaded from Microsoft’s website
(http://www. microsoft.com).
5.5 Replacing Assemblies
Should the DSP assembly (PRE99-1820) or
CPU assembly (PRE99-1815) require replace-
ment, they must be “paired-up” before use.
NOTE: Unplug the HDE-200 from the
Ethernet network, before applying
power, if either the CPU or DSP as-
semblies have been replaced.
When power is first applied to the HDE-200,
the CPU performs a scan of the local IP network
subnet looking for the presence of the DSP as-
sembly. Once the DSP assembly is found, the IP
address for that DSP board is automatically up-
dated to the DSP IP address that had been previ-
ously recorded by the CPU. Two scenarios can
occur, depending upon which assembly was re-
placed.
Scenario 1Scenario 1
Scenario 1Scenario 1
Scenario 1: The CPU is replaced.
The existing DSP IP address is returned to
the factory default (10.10.10.22).
Scenario 2Scenario 2
Scenario 2Scenario 2
Scenario 2: The DSP assembly is replaced.
The new DSP assembly will be changed
to the IP address that was assigned to the
replaced DSP assembly.
Note that the pairing process will take a bit
longer than the typical startup duration (could last
up to 5 minutes). This is normal for this pairing
process. The HDE-200 will automatically restart
again after the DSP assembly has been found and
paired with the CPU.
If the HDE-200 continually restarts, this is an
indication that the CPU is not able to pair up with
the DSP. This could be due to the CPU detecting
another HDE-200 on its local network. If this
occurs, the CPU will purposely refuse to perform
the pairing process. In this case, disconnect all
network cables from the HDE-200.
If a USB Flash Drive is connected—before start-
ing the Boot process, a boot log file will be written
to the Flash Drive. This will give a progress indi-
cation for the pairing process. Contact Harris Tech-
nical Support if continuous restarting occurs even
with the network cables disconnected.
Once the pairing is complete, review the IP ad-
dress assignments using HDE-200 Control Cen-
ter. Make any IP address adjustments that may
be necessary. Once all the network settings match
their previous settings, the connection to the Eth-
ernet network can be restored.