User's Manual

6051412900 Rev -
9
OPERATING INSTRUCTIONS
Start-Up Indications
The CARRY-CODER starts with display showing the status of the system During system initialization, the CARRY-CODER II goes
through self-test of its MPEG-2 encoder, COFDM modulator and RF sections. System initialization 10 seconds and will display as
follows:
BMS Inc. CarryCoder 2
Freq Agile 6425 – 6526 MHz
Software Ver. 2.01
Resetting /
At the completion of the initialization process, the display should look like this:
6431.25 MHz
FREQUENCY
6431.25 MHz
If the self-test finds that a sub-system does not respond correctly, a status message is displayed on the fourth line of the display.
For example, if the camera is not sending video to the transmitter, the display will include the appropriate message:
6431.25 MHz
FREQUENCY
6431.25 MHz
NO VIDEO
When the CARRY-CODER starts up, it is in the same condition as when it was powered down. This allows the user to
replace the battery with no need to touch the controls.
The CARRY-CODER II will not transmit with out video. If the System is powered up without video, the CARRY-
CODER II will automatically reboot once video input starts. The CARRY-CODER II will transmit with ASI.
Operator Menu Summary
When the control panel display shows normal system status (no Error or Warning status message) and if there is no operator use of
the control panel, the display goes dark to save battery life. Pressing any key on the control unit restores the display to show the
status of the system.
If there is a status message, the display will remain lit (will not go dark) until the problem is resolved.
The user menus can be accessed from the status screen by pressing any key. Then, the user can scroll the menus by pressing the
« Ç » and « È » keys.
After 30 seconds of keypad inactivity, the display automatically returns to the status screen.
Pressing the « Ç » and « È » keys simultaneously will cause the display to go to the status screen without having to
wait 30 seconds.