RF Output
The versions CARRY-CODER II are available for specific frequencies. Please refer to the CARRY-CODER II serial ID for
information on the operating frequency for the unit.
CARRY-CODER II FREQUENCY VERSION
S-Band C-Band
Frequency Range
1.99 to 2.50 GHz 4.4 -4.7 GHz 4.7-5.0 GHz 6.425-6.25 GHz
Channel
Bandwidth
8/7/6 MHz 6/7/8 MHz 6/7/8 MHz 6/7/8 MHz
Format
COFDM (2K carriers) COFDM (2K carriers) COFDM (2K carriers) COFDM (2K carriers)
Standard
ETS 300 744 (DVB-T) ETS 300 744 (DVB-T) ETS 300 744 (DVB-T) ETS 300 744 (DVB-T)
Output Power
50 mW, 100 mW, 250 mW
and 1W (selectable)
10 mW, 25 mW, 100 mW
and 400 mW
10 mW, 25 mW, 100 mW
and 400 mW
7 mW, 15 mW, 62 mW
and 250 mW
Shoulders at +/-
4.2 MHz
> 30 dB for 1W
> 35 dB for 250 mW or less
> 30 dB for 1W
> 35 dB for 250 mW or less
> 30 dB for 1W
> 35 dB for 250 mW or less
> 30 dB for 1W
> 35 dB for 250 mW or less
Harmonic and
Spurious
< -60 dBc (DC to 6 GHz) < -60 dBc (DC to 6 GHz) < -60 dBc (DC to 6 GHz) < -60 dBc (DC to 6 GHz)
In-Band Ripple
< +/- 1dB < +/- 1dB < +/- 1dB < +/- 1dB
Return Loss
18 dB (typical) 18 dB (typical) 18 dB (typical) 18 dB (typical)
Impedance
50 Ohms 50 Ohms 50 Ohms 50 Ohms
Connector
N - Female N - Female N - Female N - Female
Never use the CARRY-CODER II without a 50 Ohms load or antenna properly connected to the RF output, since this
could damage the RF output stage.
The system can operate with several COFDM signals located on 8 MHz adjacent channels. When analog
transmissions are active in-band it is recommended to leave a free 8 MHz channel between COFDM signals and the
active analog signals.
Power Supply Input
The CARRY-CODER II can be powered either with a battery pack or through the 4 pin connector. This enables the use of an
external power source such as a battery belt or any appropriate power supply (+11 to 32 VDC @ 4A).