INSTALLATION
Information Retrieval Commands
*POLL - Respond with unit (ID) address in appropriate time slot. If there are mul-
tiple units on the line, each will respond with a different delay after receipt of this
command.
*uSPii - Send status of input ii. Response is SuP,ii,x where x is 0 if the correspon-
ding input is high, 1 otherwise.
*uSPA - Send status of all inputs. Response is SuP,A,x,x,x,x,x,x,x,x<CR><LF>
where input 1 is first and input 8 is last. x is 0 if the corresponding input is high, 1
otherwise.
*uSR - Send status of all OUTPUTS. Response is: SuA,x,x,x,x,x,x,x,x<CR><LF>
*uU - Send Unit Information :<name(SRC-8)><version n.nn><CR><LF>
Binary Commands
All commands start with a 2Ah (ASCII *). The first byte contains the board ID and
the byte count iiibbbbb. Byte count is number of bytes after the byte containing the
byte count including checksum. The second byte contains an 8-bit command. Some
commands are followed by data bytes. Checksum is the LSByte of the sum of all
bytes preceding checksum including start. Binary commands must be received as a
packet. If 50 ms or more passes after a character is received, with no new character
following, the SRC-8 III will begin looking for a new string if no valid data packet
has been received.
Commands to SRC-8 III
Command
Additional Data Bytes Function
40h RS-232 timer off
41h RS-232 timer on
42h Set serial speed to 2400
43h Set serial speed to 9600
44h Set serial speed to 4800
45h Set serial speed to 38400
46h Enable error & good responses