Datasheet
5
Table 1. IEC/EN/DIN EN 60747-5-2 Insulation Characteristics*
Description Symbol Characteristic Unit
Installation classication per DIN VDE 0110/1.89, Table 1
for rated mains voltage ≤ 150 V
rms
for rated mains voltage ≤ 300 V
rms
for rated mains voltage ≤ 600 V
rms
I – IV
I – IV
I – III
Climatic Classication 55/100/21
Pollution Degree (DIN VDE 0110/1.89) 2
Maximum Working Insulation Voltage V
IORM
891 V
peak
Input to Output Test Voltage, Method b**,
V
IORM
x 1.875=V
PR
, 100% Production Test with t
m
=1 sec, Partial discharge < 5 pC
V
PR
1670 V
peak
Input to Output Test Voltage, Method a**,
V
IORM
x 1.5=V
PR
, Type and Sample Test, t
m
=60 sec, Partial discharge < 5 pC
V
PR
1336 V
peak
Highest Allowable Overvoltage (Transient Overvoltage t
ini
= 10 sec) V
IOTM
6000 V
peak
Safety-limiting values – maximum values allowed in the event of a failure.
Case Temperature T
S
175
°C
Input Current I
S, INPUT
400 mA
Output Power P
S, OUTPUT
1200 mW
Insulation Resistance at T
S
, V
IO
= 500 V R
S
>10
9
W
* Isolation characteristics are guaranteed only within the safety maximum ratings which must be ensured by protective circuits in application.
Surface mount classication is class A in accordance with CECCOO802.
** Refer to the optocoupler section of the Isolation and Control Components Designer’s Catalog, under Product Safety Regulations section IEC/EN/
DIN EN 60747-5-2, for a detailed description of Method a and Method b partial discharge test proles.
Dependence of Safety Limiting Values on Temperature. (take from DS AV01-0579EN Pg.7)
Regulatory Information
The ACPL-332J is approved by the following organizations:
IEC/EN/DIN EN 60747-5-2
Approval under:
IEC 60747-5-2 :1997 + A1:2002
EN 60747-5-2:2001 + A1:2002
DIN EN 60747-5-2 (VDE 0884 Teil 2):2003-01
UL
Approval under UL 1577, component recognition
program up to V
ISO
= 3750 V
RMS
. File E55361.
CSA
Approval under CSA Component Acceptance Notice #5,
File CA 88324.