Datasheet
8
Table 6. Switching Specications (AC)
Unless otherwise noted, all typical values at T
A
= 25°C, V
CC2
- V
EE
= 30 V, V
E
- V
EE
= 0 V;
all Minimum/Maximum specications are at Recommended Operating Conditions. Only Positive Supply Voltage used.
Parameter Symbol Min. Typ. Max. Units Test Conditions Fig. Note
Propagation Delay Time
to High Output Level
t
PLH
100 180 250 ns
R
g
= 10 W,
C
g
= 10 nF,
f = 10 kHz,
Duty Cycle = 50%,
I
F
= 10 mA,
V
CC2
= 30 V
1, 13,
14, 15,
16, 29
13, 15
Propagation Delay Time
to Low Output Level
t
PHL
100 180 250 ns 1, 13,
14, 15,
16, 29
Pulse Width Distortion PWD -100 20 100 ns 14, 17
Propagation Delay
Dierence Between
Any Two Parts or Channels
(t
PHL
- t
PLH
)
PDD
-350 350 ns 17, 16
Rise Time t
R
50 ns
Fall Time t
F
50 ns
DESAT Sense to
90%VO Delay
t
DESAT(90%)
0.15 0.5 µs
C
DESAT
= 100pF, R
g
= 10 W,
C
g
= 10 nF, V
CC2
= 30 V
17, 30,
37
19
DESAT Sense to
10% VO Delay
t
DESAT(10%)
2 3 µs
C
DESAT
= 100pF, R
g
= 10 W,
C
g
= 10 nF, V
CC2
= 30 V
18, 19,
20, 30,
37
DESAT Sense to Low Level
FAULT Signal Delay
t
DESAT(FAULT)
0.25 0.5 µs
C
DESAT
= 100pF, R
F
= 2.1 kW,
R
g
= 10 W, C
g
= 10 nF,
V
CC2
= 30 V
30, 37 18
DESAT Sense to DESAT
Low Propagation Delay
t
DESAT(LOW)
0.25 µs
C
DESAT
= 100pF, R
F
= 2.1 kW,
R
g
= 10 W, C
g
= 10 nF,
V
CC2
= 30 V
30, 37 19
DESAT Input Mute t
DESAT(MUTE)
5 µs 37 20
RESET to High Level FAULT
Signal Delay
t
RESET(FAULT)
0.3 1 2.0 µs
C
DESAT
= 100pF, RF = 2.1 kW,
Rg = 10 W, Cg = 10 nF,
V
CC1
= 5.5V, V
CC2
= 30 V
0.8 1.5 2.5 µs
C
DESAT
= 100pF, R
F
= 2.1 kW,
Rg = 10 W, Cg = 10 nF,
V
CC1
= 3.3V, V
CC2
= 30 V
Output High Level Common
Mode Transient Immunity
|CM
H
| 15 25 kV/µs T
A
= 25°C, I
F
= 10 mA
V
CM
= 1500 V, V
CC2
= 30 V
31, 32,
33, 34
21
Output Low Level Common
Mode Transient Immunity
|CM
L
| 15 25 kV/µs T
A
= 25°C, V
F
= 0 V
V
CM
= 1500 V, V
CC2
= 30 V
31, 32,
33, 34
22