Datasheet

10
Electrical Specifications (DC)
Over recommended temperature (T
A
= 0°C to 70°C) unless otherwise specified. See note 9.
Parameter Sym. Device Min. Typ.* Max. Units Test Conditions Fig. Note
Current CTR HCPL-2530/ 7 18 50 % T
A
= 25°CI
F
= 16 mA, 1, 2 1, 2
Transfer 0530 V
CC
= 4.5 V 4
Ratio 5 V
O
= 0.5 V
HCPL-2531/ 19 24 50 % T
A
= 25°C
0531
HCPL-4534/ 15
0534
Logic Low V
OL
HCPL-2530/ 0.1 0.5 V T
A
= 25°CI
O
= 1.1 mA I
F
= 16 mA, 1 1
Output 0530 V
CC
= 4.5 V
Voltage 0.5 I
O
= 0.8 mA
HCPL-2531/ 0.1 0.5 V T
A
= 25°CI
O
= 3.0 mA
0531
HCPL-4534/ 0.5 I
O
= 2.4 mA
0534
Logic High I
OH
0.003 0.5 µAT
A
= 25°C V
CC
= V
O
= 5.5V,I
F
= 0 mA 6 1
Output I
F
= 0 mA
Current
50 T
A
= 25°C V
CC
= V
O
= 15V,
I
F
= 0 mA
Logic Low I
CCL
100 400 µAI
F
= 16 mA, V
O
= Open,
Supply V
CC
= 15 V
Current
Logic High I
CCH
0.05 4 µAI
F
= 0 mA, V
O
= Open,
Supply V
CC
= 15 V
Current
Input V
F
1.5 1.7 V T
A
= 25°C31
Forward I
F
= 16 mA
Voltage 1.8
Input BV
R
5VI
R
=10 µA1
Reverse
Breakdown
Voltage
Temperature V
F
-1.6 mV/ I
F
= 16 mA
Coefficient T
A
°C
of Forward
Voltage
Input C
IN
60 pF f = 1 MHz, V
F
= 0 V 1
Capacitance
*All typicals at T
A