Datasheet
6
Switching Specications
For 0°C ≤ T
A
≤ 70°C, 4.5 V ≤ V
CC
≤ 20 V, all typicals at T
A
= 25°C and V
CC
= 5 V unless otherwise noted. See note 12.
Parameter Symbol Min. Typ. Max. Units Test Conditions Fig. Note
Propagation Delay Time t
PLH
0.3 1.6 µs C
O
= 1000 pF, 5, 6, 6
to Logic High Output Level C
L
= 15 pF, 7
I
O
= 20 mA
Propagation Delay Time t
PHL
0.2 1.0 µs C
O
= 1000 pF, 5, 6, 7
to Logic Low Output Level C
L
= 15 pF, 7
I
O
= 20 mA
Propagation Delay Time t
PLH
- t
PHL
0.1 µs I
O
= 20 mA
Skew
Output Rise Time t
r
16 ns I
O
= 20 mA, 6, 8 8
(10-90%) C
O
= 1000 pF,
C
L
= 15 pF
Output Fall Time t
f
23 ns I
O
= 20 mA, 6, 8 9
(90-10%) C
O
= 1000 pF,
C
L
= 15 pF
Common Mode Transient |CM
H
| 1,000 10,000 V/µs V
I
= 2 V, 9, 10 10
Immunity at Logic High T
A
= 25°C
Output Level V
CM
= 50 V (peak),
V
CC
= 5 V
I
O
(min.) = 12 mA
Common Mode Transient |CM
L
| 1,000 10,000 V/µs V
I
= 0.8 V, 9, 10 11
Immunity at Logic Low T
A
= 25°C
Output Level V
CM
= 50 V (peak),
V
CC
= 5 V
I
O
(max.) = 3 mA
Package Characteristics
For 0°C ≤ T
A
≤ 70°C, unless otherwise specied. All typicals at T
A
= 25°C.
Parameter Symbol Min. Typ. Max. Units Test Conditions Fig. Notes
Input-Output Momentary V
ISO
3750 V rms RH ≤ 50%, t = 1 min,
Withstand Voltage* T
A
= 25°C 5, 13
Resistance, Input-Output R
I-O
10
12
ohms V
I-O
= 500 V dc 5
Capacitance, Input-Output C
I-O
1 pF f = 1 MHz,
V
I-O
= 0 V dc 5
*The Input-Output Momentary Withstand Voltage is a dielectric voltage rating that should not be interpreted as an input-output continuous volt-
age rating. For the continuous voltage rating refer to the IEC/EN/DIN EN 60747-5-2 Insulation Characteristics Table (if applicable), your equipment
level safety specication, or Avago Application Note 1074, “Optocoupler Input-Output Endurance Voltage.”