Installation Guide

9
11. INSTALL THE DECORATIVE FLUE (continued)
DucteD INstallatIoN:
Slide up the upper flue until it is aligned with its mounting bracket. The bracket must
be inside the flue. Secure the upper flue to its bracket using 2 M4 x12 Phillips 9 mm
round head screws.
NOTE: Duct not shown in illustration to ease understanding.
Remove protective plastic film covering the upper flue and the hood.
HO0299
upper Flue mouNtINg bracket
FroNt vIew
upper
Flue
12. REINSTALL GREASE FILTERS
all INstallatIoNs:
To reinstall the grease filters, align rear filter tabs with slots in the hood.
Pull down the metal latch tab, push each filter into position and release.
Make sure filters are securely engaged after installation.
HD1149
NoN-DucteD INstallatIoN:
Install a charcoal filter on each aluminum grease filter back (A). Hold the
charcoal filter in place by inserting both ends of the 3 metal strips in each
aluminum grease filter frame (B).
HA0145
AB
HO0293
NoN-DucteD INstallatIoN:
Slide up the upper flue until it is aligned with the plenum. Secure the upper flue to the
plenum using 2 M4 x12 Phillips 9 mm round head screws.
Remove protective plastic film covering the upper flue and the hood.