Instructions / Assembly

4
7. Connect 4-in. round duct.
Pull existing ducting through housing discharge opening and tape ducting
to duct connector. Push connector/ducting back through opening. Engage
tabs and secure with screw from parts bag.
1
2
3
TABS
*
8. Install blower.
Re-install blower removed in Step1. Secure blower with 2 screws from
parts bag and plug blower into black receptacle.
5. Connect wiring.
Bend tab to expose desired access
hole. Connect power cable to
housing with appropriate UL
approved connector. Connect black
to black, white to white, black to
red and green to green or bare wire.
Re-install wiring panel and secure
with screw from parts bag.
WIRING DIAGRAM
99045970A
SWITCH BOX
LIGHT
FAN
DUAL CONTROL
(purchase separately)
WHITE
BLACK
RED
GROUND
(bare)
WIRING PLATE
120 VAC LINE IN
RECEPTACLE
(FAN)
RECEPTACLE
(LIGHT)
6. Connect wiring.
Bend tab to expose desired access
hole. Connect power cable to
housing with appropriate UL
approved connector. Connect black
to black, white to white, black to
red and green to green or bare
wire. Re-install wiring panel and
secure with screw from parts bag.
Depending upon model - your
grille may look different.
If grille spring becomes
dislodged from grille -
snap it back into place
as shown.
7. Finish ceiling - then skip to Step 8.
6. Mount fan to ceiling structure.
Access all mounting holes in
the fan housing by removing
the panel holding the LED
driver. Insert housing
through ceiling opening and
position so that housing
flanges touch ceiling. Secure
housing to ceiling structure
using standard drywall or
wood screws in locations
shown. *Center hole
optional. Re-attach the panel
holding the LED driver.
2
10½-in.
9¾-in.
JOIST
3. Remove old fan and prepare ceiling.
Existing fan housings are typically attached to the structure:
with screws, nails, or staples, which must be removed.
with hangers or rails which are fastened to joists and must be
removed along with housing.
A pry bar may be needed to remove the old housing.
1
4. Fold mounting
ears at against
housing.
RETROFIT INSTALLATION
Enlarge ceiling opening
(if necessary) to 9¾”
parallel to joist) by 10½”
(perpendicular to joist).
(Some models have a
cut-out template on side
of carton.) Leave ductwork
and wiring in place.
9. Install grille.
Plug in light. Squeeze grille springs and insert into slots in housing.
Push grille up against ceiling.