Installation & Assembly

Broan-NuTone LLC Hartford, Wisconsin www.broan.com 800-558-1711
C
L
7
7
8
42
5
8” = bottom of hood 30” above cooktop
48
5
8” = bottom of hood 36” above cooktop
3
15
16
FRAMING BEHIND
DRYWALL
1
9
16
WALL STUDS
B58 SERIES WIRING
B58 SERIES MOUNTING
NOTE: Minimum hood distance above cooktop must not be less than 30”.
A maximum of 36” above the cooktop is highly recommended for best capture of cooking impurities.
Distances over 36” are at the installer and users’ discretion; and if ceiling height and flue length permit.
MOUNTING BRACKET
LOCATION
(ABOVE 36” HIGH
COOKTOP)
CEILING DUCT MOUNTING DISTANCE ABOVE 36” HIGH COOKTOP (SEE NOTE BELOW)
HEIGHT METHOD 30” 31” 32” 33” 34” 35” 36”
MOUNTING BRACKET LOCATION ABOVE 36” HIGH COOK TOP
8 FEET DUCTED OR 42-5/8” 43-5/8” 44-5/8”
NONDUCTED
9 FEET DUCTED OR 42-5/8” 43-5/8” 44-5/8” 45-5/8” 46-5/8” 47-5/8” 48-5/8”
NONDUCTED
10 FEET DUCTED WITH 42-5/8” 43-5/8” 44-5/8” 45-5/8” 46-5/8” 47-5/8” 48-5/8”
FEXTK42
1. GROUNDING INSTRUCTIONS
This appliance must be grounded. In the event of an electrical short circuit,
grounding reduces the risk of electric shock by providing an escape wire for the
electric current. This appliance is equipped with a cord having a grounding wire
with a grounding plug. The plug must be plugged into an outlet that is properly
installed and grounded.
NOTE:
A recessed “clock” outlet is recommended.
2. Position the electrical outlet within the space covered by the decorative flue and
where it will not interfere with the round duct. Make sure the outlet is no further
than 14” from where the cord exits from the hood and that the outlet does not
interfere with a mounting bracket fastening area or where the decorative flue
touches the wall.
14”
MAX.
1. Construct wood wall framing that is flush with interior surface of wall studs.
Make sure:
a) the framing is centered over installation location.
b) the height of the framing will allow the mounting bracket
to be secured to the framing within the dimensions
shown.
2. After wall surface is finished, carefully center and level the hood
mounting bracket and secure it to wall framing with (3) #8 x 1-1/2”
mounting screws. Tighten the screws completely.
NOTE:
On 8-ft. ceilings
Hood distance above cooktop is:
Minimum 30”, Maximum 32-3/4” (for ducted discharge)
Minimum 30”, Maximum 30” (for non-ducted discharge)
On 9-ft. ceilings
Hood distance above cooktop is:
Minimum 30”, Maximum 36” (for both ducted and non-ducted discharge)
On 10-ft. ceilings
Hood distance above cooktop is:
Minimum 30”, Maximum 36” (for both ducted and non-ducted discharge).
NOTE: 10-ft. ceilings require 10-ft. Flue Extension, Model FXN58SS