SPECIFICATION SHEET
Broan-NuTone LLC, 926 West State Street, Hartford, WI 53027 (1-800-637-1453)
REFERENCE QTY. REMARKS Project
Location
Architect
Engineer
Contractor
Submitted by Date
TYPICAL SPECIFICATION
Range hood shall be Broan Model F40000.
Unit shall be convertible between ducted using a washable
aluminum filter (included) and non-ducted (purchase non-
ducted filter separately).
Motor to be permanently lubricated. RPM not to exceed 2850.
Unit shall have a two-speed fan switch with separate light
switch.
Sides shall be mitered and bottom edge hemmed - with no
sharp edges.
Air delivery shall be no less than 160 CFM and sound levels
no greater than 6.5 Sones (3¼" x 10" horizontal and vertical
discharge) or 190 CFM at 6.5 Sones (7" round discharge).
All air and sound ratings shall be certified by HVI.
Unit shall be U.L. listed.
Constructed with quality and good looks, the F40000
is superior to the competition whether ducted
vertically, horizontally, or non-ducted.
FEATURES
Two speed fan control
Polymeric blade and light lens (accepts up to 75W bulb)
Washable aluminum filter
Converts to non-ducted by removing cover plate from front of
hood and installing the non-ducted filter (purchase separately)
Mitered sides and hemmed bottom for safety and good looks
3¼" x 10" damper/duct connector included
7" round duct adapter plate included. 7" round damper
purchase separately.
Available in 24, 30", 36" and 42" widths
Contemporary styling in White, Almond, Biscuit, Black,
Stainless Steel (all widths), and Black Stainless Steel (30"
width only)
91D 99043020F
F40000 SERIES
TWO-SPEED
4-WAY CONVERTIBLE
RANGE HOOD
SPECIFICATIONS
VOLTS AMPS RPM CFM SONES DUCT
120 2.5 2850 160 6.5 3¼” x 10” (H)
120 2.0 2850 160 6.5 3¼” x 10” (V)
120 2.0 2850 190 6.5 7” Round (V)
120 2.0 2850 Non-ducted
HVI-2100 CERTIFIED RATINGS comply with new
testing technologies and procedures prescribed by the
Home Ventilating Institute, for off-the-shelf products, as
they are available to consumers. Product performance
is rated at 0.1 in. static pressure, based on tests
conducted in a state-of-the-art test laboratory. Sones
are a measure of humanly-perceived loudness, based
on laboratory measurements.