Instructions / Assembly

Page 2
VENTILATION FAN MODEL QTXE150
TYPICAL
INSTALLATIONS
Housing
mounted to
I-joists.
Use I-joist
spacer block
(provided).
Housing mounted
anywhere between
trusses using
hanger bars.
Housing
mounted
anywhere
between
I-joists
using
hanger bars.
Housing
mounted to
joists.
Housing
mounted
anywhere
between
joists
using
hanger bars.
Housing
mounted to
truss.
PLAN THE INSTALLATION
Cooking
Equipment
Floor
COOKING AREA
Do not install above or
inside this area.
45
o
45
o
NOT FOR USE IN
A COOKING AREA.
ROOF CAP*
(with built-in
damper)
WALL CAP*
(with built-in
damper)
6-IN. ROUND
ELBOWS*
6-IN. ROUND
DUCT*
FAN
HOUSING
Seal gaps
around
housing.
Seal duct
joints with
tape.
Keep duct
runs short.
INSULATION
(Place around and
over fan housing.)
POWER
CABLE*
*Purchase
separately.
OR
The ducting from this fan to the outside of the building has a strong effect on the
air flow, noise and energy use of the fan. Use the shortest, straightest duct routing
possible for best performance, and avoid installing the fan with smaller ducts than
recommended. Insulation around the ducts can reduce energy loss and inhibit
mold growth. Fans installed with existing ducts may not achieve their rated airflow.