Specification Sheet
ATTIC MIN.
MODEL VOLTS AMPS RPM CFM MAX. SQ. FT. INLET AREA
350 120 3.6 1000 1050 1500 3.5 SQ. FT.
355 120 4.3 1050 1200 1715 4.0 SQ. FT.
356 120 8.0 1500 1600 2285 5.5 SQ. FT.
358 120 4.3 1050 1200 1715 4.0 SQ. FT.
SPECIFICATION SHEET
Broan-NuTone LLC, 926 West State Street, Hartford, Wisconsin 53027 (1-800-637-1453)
REFERENCE QTY. REMARKS Project
Location
Architect
Engineer
Contractor
Submitted by Date
10D 99041108H
ROOF MOUNTED
POWERED ATTIC
VENTILATORS
Powerful and easy to install, these units supplement or
replace air conditioning by removing the blanket of hot,
trapped air from attics - automatically.
FEATURES
•
Precision balanced 14" metal blade for maximum air flow
- minimum sound level
•
PVC plastic dome provides ultraviolet protection and superior
durability (Models 350, 355, 356)
•
.050 aluminum dome (Model 358)
•
23 gage metal flashing - allows for nailing and hot tar application
•
Mesh bird screen
•
Built-in adjustable thermostat - for automatic operation at your
chosen temperature level
•
Thermally protected, permanently lubricated motor
•
Mounts easily between rafters - installation
template included
INSTALLATION ACCESSORIES (purchase separately):
•
Model 445 Aluminum Roof Vent, 14" x 16" base, 8"
opening, 4-1/2" high, FREE AREA: 45 sq. in. per vent.
•
Model 446 Aluminum Eave Vent, 4" x 16",
FREE AREA: 22 sq. in. per vent.
•
Model 447 Aluminum Eave Vent, 8" x 16",
FREE AREA: 54 sq. in. per vent.
CONTROLS DESIGNED FOR USE WITH THESE PRODUCTS
(purchase separately):
• Model 69V (Ivory)/69W (White) Single-Function Control
• Model 68V (Ivory)/68W (White) Two-Function Control
• Model 72V (Ivory)/72W (White) Electronic Variable Speed
Control- 6 amp (
not for use with Model 356)
SPECIFICATIONS
TYPICAL SPECIFICATION
Roof Mounted Attic Ventilator shall be Broan Model 350
(355) (356) (358).
Ventilator shall have metal blade and flashing plate. Bird screen
to be included.
Dome to be ultraviolet resistant plastic. (.050 Approx. 18 gage
aluminum). Motor to be thermally protected and permanently
lubricated. RPM not to exceed 1000 (Model 350), 1100 (Models
355 and 358), 1500 (Model 356).
Ventilator shall have a built-in adjustable thermostat and mount
easily between rafters or wall studs.
Air delivery shall be no less than 1050 CFM (Model 350), 1200
CFM (Models 355 and 358), 1600 CFM (Model 356). All ratings
shall be certified by HVI. Units to be U.L. Listed.
HVI-2100 CERTIFIED RATINGS comply with new testing
technologies and procedures prescribed by the Home
Ventilating Institute, for off-the-shelf products, as they
are available to consumers. Product performance is
rated at 0.1 in. static pressure, based on tests conducted
in AMCA’s state-of-the-art test laboratory. Sones are a
measure of humanly-perceived loudness, based on
laboratory measurements.