Manual
PREPARE THE HOOD FiG.F
1. Unpack hood and check contents. You should re-
ceive:
1 - Aluminum Filter (40000 and 42000 & 42000D
hoods only)
1 - 3-1/4" x 10" Damper/Duct Connector (mounted
inside of hood for shipping only) (40000
hood only)
1 - Ductfree Microtek ® System I Filter (41000
hood only)
1 - 7" Round Damper (42000D hoods only.)
2. Remove wiring box cover. Under cover find:
1 - Plastic Bag containing loose mounting hard-
ware
3. Remove top or rear electrical knockout. (FIG. 2)
4. (40000 hood ONLY) Remove duct knockout. In-
sert screwdriver under edge of knockout, break
tabs, and peel knockout back with pliers. (FIG. 3)
5. (40000 hood ONLY) Install damper/duct connec-
tor over opening made in STEP 4. Use #8B sheet
metal screws provided. (FIG. 3)
(42000 hood ONLY) Install Model 87 round damper
(purchase separately) over opening in top of hood.
(42000D hood ONLY - Install 7" round damper (in-
cluded) over opening on top of hood.
PREPARE THE
INSTALLATION LOCATION
Omit STEP 1 if hood will be installed under cabinets
with flush bottom.
1. (For installation on recessed bottom cabinets only)
Attach a wood filler strip at each side of recessed
area under cabinet. Use two 1" x 2" strips cut to
length. If recess is deeper than 1" use thicker strips.
Attach strips with 1-1/4" wood screws, 3" from each
end of strip. See FIG. 4.
2. Measure and mark the following (FIGS. 5A & 5B):
a.) Electrical wiring opening in wall or cabinet.
b.) Duct opening in wall or cabinet (40000, 42000
& 42000D hoods ONLY).
WARNING
I
WHEN CUTTING OR DRILLING INTO WALL OR
CABINET, BE CAREFUL NOT TO CUT EXISTING
]ELECTRICAL WIRING.
3. Use 1-1/4" bit to drill opening for electric wiring.
4. Cut out duct opening in wall or cabinet with saber
saw or keyhole saw.
5. Center hood in installation opening and trace key-
hole slots onto wood filler strips on cabinet bottom.
6. Screw four #10 x 7/8 wood screws into exact center
of narrow end of traced keyhole slots. Allow 3/8" of
screws to project, so that hood can be fitted into place
later.
ROOF CAP 634
CASQUETE DE TECHO 634
3-1/4" x 10" TO 6" ROUND
DUCT TRANSITION 411
ADAPTADOR DE UNA
SALIDA DE EXTRACTOR
DE
3-1/4 PLG. x 10 PLG. A UN
DUCTO CIRCULAR
6" ROUND DUCT 406
REDONDO
DE 6 PLG. 406
WIRING BOX COVER
FIG. 1 CUBIERTA DE LA CAJA DE CABLEADO
DUCTFREE
MICROTEK®
(SOLO
PARALO6 S DAMPER/DUCT
_OS CONNECTOR (40000
HOOD ONLY)
40000, 42000
Y42000D) T ROUND DAMPER CONECTOR DEL
(42000D HOOD ONLY) DUCTO/REGULADOR
REGULADOR REDONDO (SOLO PARA EL
DE 7 PULG. (SOLO PARA MODELO 40000)
EL MODELO 42000D)
FIG. 2
FIG. 3
ELECTRICAL
KNOCKOUTS
TAPONES
HINGE PINS
PASADORES DE
3ISAGRA
DUCT
KNOCKOUTS
TAPONES DEL
DUCTO
FIG. 4
...... ¢',',,
/" , \
,/",,:,.... i//
........................
PREPARANDO
EL EXTRACTOR
1. Desempaque el extractor y revise el contenido de la
caja. Usted debe encontrar:
1 - Filtro de aluminio (solamente extractores modelos
40000, 42000 y 42000D)
1 - Conector de ducto/regulador de 3-1/4 pig. x 10
pig. (montado dentro del extractor para facilitar
el embarque) (solamente extractores modelo 40000)
1 - Sistema de filtro Ductfree Microtek ® System
1 - Regulador de 7 pulg. (campanas de 42000D
solamente.)
2. Retire la cubierta de la caja de cableado. (FIG. 1)
Bajo la cubierta encontrara:
1-Bolsa de pldtstico que contiene las piezas
necesarias para la instalacion
3. Retire el tap6n electrico trasero superior. (Fig. 2)
4. (SOLAMENTE extractores modelo 40000) Retire el
tapon trasero superior. Coloque un desarmador
debajo del extremo del tapon, rompa los apendices y
retire el tap6n con unas pinzas. (FIG. 3)
5. (SOLAMENTE extractores modelo 40000) Instale el
conector del ducto/regulador sobre la abertura hecha
en el PASO 4. Utilice el tornillo de lamina negra #8B
proporcionado en la bolsa de plastico. (FIG. 3)
(SOLAMENTE extractores modelo 42000) Instale el
regulador Modelo 87 (comprado por separado) sobre
la abertura en la parte superior del extractor.
(Campana de 4200D SOLAMENTE - Instale regulador
de 7 pulg. (incluido) sobre la abertura en la tapa de la
campana.
ACONDICIONE EL LUGAR
DE LA INSTALACION
Si el extractor va a ser instalado bajo gabinetes con suelo
nivelado, omita el PASO 1.
1. (Solamente para la instalacion en los gabinetes con
espacios libres) Coloque una pieza de madera en cada
uno de los lados para rellenar el Area libre debajo del
gabinete. Utilice dos tiras de madera de 1 pig. x 2 pig.
de Iongitud. Si el Area libre tiene mas de 1 pig. de
profundidad, utilice piezas de madera m_ts gruesas.
Ajuste las piezas con tornillos para madera de 1-1/4
pig., a 3 pig. de los extremos. Consulte la FIG. 4.
2. Mida y marque Io siguiente (FIGS. 5A y 5B):
a.) La abertura del cableado electrico en la pared
o el gabinete.
b.) La abertura para el ducto en la pared o el gabinete
(SOLAMENTE extractores modelos 40000, 42000
y 42000D).
ADVERTENCIA
/
CUANDO ESTE CORTANDO O PERFORANDO LA /
PARED O EL GABINETE, ASEGURESE DE NO
J
CORTAR EL CABLEADO ELECTRICO EXlSTENTE.
3. Utilice un taladro de 1-1/4 pig. para hacer la abertura
para el cableado electrico.
4. Haga un corte en la pared o el gabinete, para la entrada
del ducto, con un serrucho ouna sierra de punta o de
calador. (Si la pared es de concreto, haga las
operaciones necesarias para la instalacion.)
5. Centre el extractor en la entrada de la instalaci6n y
marque las ranuras en las piezas de madera que
rellenan el espacio libre en la parte inferior del gabinete.
6. Ajuste 4 tornillos para madera #10 x 7/8 justo en el
centro del extremo angosto de las ranuras marcadas.
Permita que los tornillos salgan 3/8 pig. para que el
extractor pueda ser colocado en su lugar.