Installation Guide

INSTALLATION INSTRUCTIONS
ALL ELECTRICAL CONNECTIONS MUST BE IN ACCORDANCE WITH LOCAL CODES, ORDINANCES,
OR NATIONAL ELECTRICAL CODE, AS APPLICABLE. IF YOU ARE UNFAMILIAR WITH METHODS OF
INSTALLING ELECTRICAL WIRING, SECURE THE SERVICES OF A QUALIFIED ELECTRICIAN.
Turn off power and lock out sevice panel before installing, wiring, or servicing this product.
To prevent serious injury from electrical shock or damage to electrical components - DO NOT WIRE HOT!
Warranty is void if miswired.
1. Turn off power and lock out service panel before wiring control.
2. Install a 2¾" deep switch box if using 14-gauge wire. Install a 3½" deep switch box if using 12-gauge
wire. (Single-gang box for time control only. Double-gang box for time control w/rocker switch.)
3. Attach incoming power line and fan power line to switch box. It may be necessary to use two side
knockouts for some applications.
4. Make electrical connections as shown. Use proper electrical connectors. Make sure that time control,
(rocker switch) and applicance are properly grounded.
5. Tuck wires into box. Fasten time control (and rocker switch) to box with mounting screws. Note "TOP"
direction shown on time control face.
6. Attach switch plate using color-matched oval head screws.
7. Slip the time dial plate over the threaded extension with "OFF" mark at top. Fasten with nut. DO NOT
OVERTIGHTEN.
8. Push knob onto time control shaft. The knob has a "D-shaped" hole which matches the "D-shaped" shaft
on the time control.
WIRING DIAGRAMS
BROAN-NUTONE ONE YEAR LIMITED WARRANTY
Broan-NuTone warrants to the original consumer purchaser of its products that such products will be free from
defects in materials or workmanship for a period of one year from the date of original purchase. THERE ARE NO
OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
During this one-year period, Broan-NuTone will, at its option, repair or replace, without charge, any product or part
which is found to be defective under normal use and service.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS, TUBES, HALOGEN AND
INCANDESCENT BULBS, FUSES, FILTERS, DUCTS, ROOF CAPS, WALL CAPS AND OTHER ACCESSORIES FOR
DUCTING. This warranty does not cover (a) normal maintenance and service or (b) any products or parts which have
been subject to misuse, negligence, accident, improper maintenance or repair (other than by Broan-NuTone), faulty
installation or installation contrary to recommended installation instructions.
The duration of any implied warranty is limited to the one-year period as specified for the express warranty. Some
states do not allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you.
BROAN-NUTONE’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN-NUTONE’S OPTION, SHALL BE THE
PURCHASER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. BROAN-NUTONE SHALL NOT BE
LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION
WITH PRODUCT USE OR PERFORMANCE. Some states do not allow the exclusion or limitation of incidental or
consequential damages, so the above limitation or exclusion may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. This
warranty supersedes all prior warranties.
To qualify for warranty service, you must (a) notify Broan-NuTone at the address or telephone number below, (b)
give the model number and part identification and (c) describe the nature of any defect in the product or part. At the
time of requesting warranty service, you must present evidence of the original purchase date.
Broan-NuTone LLC, 926 W. State Street, Hartford, Wisconsin 53027 www.broan.com 800-558-1711
Broan-NuTone Canada, Inc., 1140 Tristar Drive, Mississauga, Ontario L5T 1H9 www.broan.ca 877-896-1119
TIME CONTROL OPERATING INSTRUCTIONS
Depending on model, time control will operate fan at any interval from 1 minute
up to 15 minutes, 1 minute up to 60 minutes, or 1 hour to 12 hours. Turn indicator
knob past "TURN PAST" and then to desired time setting. Timer will automatically
shut fan off at the end of the set time period.
Timer will provide continuous fan operation when indicator knob is turned to
"HOLD" position. (Not on 15-min. time control).
TIME CONTROL W/ DUAL ROCKER SWITCH
TIME CONTROL W/ ROCKER SWITCH
LOAD
TIME
CONTROL
1
NO
1
C
2
C
2
NC
BLACK
WHITE
GROUND
WHITE
BLACK
GROUND
SWITCH BOX APPLIANCE
120 VAC
LINE IN
OR
LOW VOLTAGE
SOURCE
(30V OR LESS)
GROUND
TIME CONTROL
Time Control w/ Dual Rocker Switch and double-gang switch box shown.
TIME DIAL
PLATE
NUT
KNOB
COLOR-MATCHED
OVAL-HEAD
SCREW (2 or 4)
MOUNTING
SCREW (2 or 4)
TIME CONTROL
(GROUND CONNECTION
ON TOP)
THREADED
EXTENSION
STANDARD 2-GANG
SWITCH BOX
SWITCH PLATE
TIME CONTROL • TIME CONTROL W/ ROCKER SWITCH
• TIME CONTROL W/ DUAL ROCKER SWITCH
IMPORTANT NOTE
The time control is designed with "NO" (Normally Open)
and "NC" (Normally Closed) contacts. The standard instal-
lation uses the "NO" contacts (see wiring diagrams below).
Note
For "push-in" wire: use #14-gauge only.
For screw terminals: Use #12-gauge or #14-gauge solid copper wire only.
99043745B
LOAD 1
TIME
CONTROL
1
NO
1
C
2
C
2
NC
BLACK
WHITE
GROUND
WHITE
RED
GROUND
SWITCH BOX APPLIANCE
GROUND
ROCKER
SWITCH
LOAD 2
120 VAC
LINE IN
BLACK
LOAD 1
TIME
CONTROL
1
NO
1
C
2
C
2
NC
BLACK
WHITE
GROUND
WHITE
RED
GROUND
SWITCH BOX APPLIANCE
GROUND
DUAL
ROCKER
SWITCH
LOAD 3
120 VAC
LINE IN
BLACK
LOAD 2
WHITE *
* CODE REQUIRES BOTH ENDS OF THIS WIRE BE COLORED
SINCE IT IS SWITCHED. USE A FELT-TIPPED MARKER.