Specification Sheet

Broan-NuTone LLC Hartford, Wisconsin www.broan.com 800-558-1711
REFERENCE QTY. REMARKS Project
Location
Architect
Engineer
Contractor
Submitted by Date
SPECIFICATION SHEET
51H 99045366A
MODELS A50L, A70L
INVENT
TM
SERIES
FAN / LIGHTS
DESCRIPTION
BLOWER:
Plug-in, permanently lubricated motor - engineered for
continuous operation
Dynamically balanced centrifugal blower wheel for quiet,
efficient performance
Low RPM for quiet operation
HOUSING:
Rugged, 26 gauge, galvanized steel construction
Polymeric, 4” duct connector with tapered sleeve and no
metallic clatter
5-3/4” height allows for 2” x 6” ceiling installations
Sturdy, easy, four-point mounting directly to joist
Can be mounted in ceilings up to 7/12 pitch
GRILLE:
Polymeric construction
Innovative design - the result of extensive research with
designers and consumers
100W max. incandescent A19 type bulb or energy
efficient equivalent bulb with Maximum Overall Length
(M.O.L.) of 4.4" or less (bulb not included)
Durable steel reflector with white enamel finish
CONTROLS (Purchase separately):
Refer to Broans catalog for a complete line of
accessories to effectively adapt these fans to your
construction requirements.
U.L. Listed for use over bathtubs and showers when
connected to a GFCI protected branch circuit (ceiling
mount only).
U.L. Listed for use in insulated ceilings (TYPE I.C.)
1-Year Warranty
TYPICAL SPECIFICATION
Fan / Light shall be Broan Model A50L (A70L).
Fan / Light shall have corrosion resistant galvanized steel
housing with four-point mounting capability. It shall be
ducted to a roof or wall cap using 4” round ductwork.
Blower assembly shall be removable, have a centrifugal-
type blower wheel and a permanently lubricated motor
designed for continuous operation.
Non-metallic damper/duct connector shall be included.
Bulb shall be 100W max. A19 type incandescent or energy
efficient equivalent bulb with Maximum Overall Length
(M.O.L.) of 4.4" or less (bulbs not included).
Air delivery shall be no less than the airflow values and
no greater than the sound level values listed in the HVI
Performance Specifications provided in this specification
(see following chart). All air and sound ratings shall be
certified by HVI.
Ceiling Ventilator shall be U.L. Listed for use in insulated
ceilings (Type I.C.) and for use over bathtubs and showers
when connected to a GFCI protected branch circuit.

Summary of content (2 pages)